Building Products Listing Program | |||||||||||||||||||||||||||||||||||||||
Class: | Roofing Underlayment | ||||||||||||||||||||||||||||||||||||||
Customer: | System Components Corporation | ||||||||||||||||||||||||||||||||||||||
Location: | PO Box 2432, Issaquah, WA 98027 | ||||||||||||||||||||||||||||||||||||||
Listing No.: | B1041-1 | ||||||||||||||||||||||||||||||||||||||
Project No.: | |||||||||||||||||||||||||||||||||||||||
Effective Date: | March 30, 2012 | ||||||||||||||||||||||||||||||||||||||
Last Revised: | July 3, 2013 | ||||||||||||||||||||||||||||||||||||||
Expires: | N/A | ||||||||||||||||||||||||||||||||||||||
Product: |
FelTex®,
ProTex®
and
CoverPro™ 15 High Performance
Roof Wraps: Roll roofing underlayment, for use as secondary
protection under roof tile or shingle roof covering systems.
48 inches
200 ft (76.20 m)
or
48 inches
200 ft (76.20 m)
or
40 inches
(1.02 m)
Or
42 inches
200 ft (76.20 m)
or
2.2 lbs/100
ft2 |
||||||||||||||||||||||||||||||||||||||
Website: | |||||||||||||||||||||||||||||||||||||||
Additional Info: | |||||||||||||||||||||||||||||||||||||||
Standards: |
CAN/CSA-A220.1 “Installation
of Concrete Roof Tiles”. CAN/CSA-A123.3 “Asphalt
Saturated Organic Roofing Felt”. ASTM
D2626 “Standard Specification for Asphalt-Saturated
and Coated Organic
Felt Base Sheet Used in Roofing”. ASTM D226 “Standard
Specification for Asphalt-Saturated Organic Felt Used in Roofing and
Waterproofing”.1 TAS 104-95 ” Test Procedure for Nail-on Underlayment for Use with Discontinuous Roof Systems”.See Limitations of Use
The rating for the noted System Components
products can be found in ratings section of this listing.
|
||||||||||||||||||||||||||||||||||||||
Ratings: |
The following ratings apply to System Components ProTex®,
FelTex® and
CoverPro™
15 products:
Note 1: CSA A123.3, ASTM D2626, and ASTM D226 outline specifications for asphalt-impregnated organic felt materials. System Components ProTex®, FelTex® and CoverPro™ 15 high performance underlayment products were tested and found to comply with the performance specifications outlined in CSA A123.3, ASTM D2626 and ASTM D226 for the classifications noted. |
||||||||||||||||||||||||||||||||||||||
Limitations of Use: | Systems Components ProTex® and FelTex® high performance underlayment products, when installed for use in High Velocity Hurricane Zones, require roof covering products including tile, are properly braced on blocked to ensure tile slippage is avoided where roof coverings are in direct contact with the noted System Component Products. | ||||||||||||||||||||||||||||||||||||||
Label: |
Product
units are marked with the following information:
1.
Manufacturer’s Name
2.
Product Name.
3.
Month and Year of Manufacture
4.
QAI logo with the “US” and
“C” identifier
5.
Listing number
6.
Standard numbers and ratings
7.
ICC-ES ESR-1293(ProTex®
and FelTex® products) |
||||||||||||||||||||||||||||||||||||||
Note: |
These
products are subjected to limitations as specified above and must be
installed in accordance with the manufacturers’ instructions.
Authorities having jurisdiction should be consulted regarding
allowable applications. |
||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
The materials, products or systems listed in this directory have
been qualified to bear the QAI Listing Mark under the conditions
stated with each Listing. Only those products bearing the QAI
Listing Mark are considered to be listed by QAI.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request. |
|||||||||||||||||||||||||||||||||||||||
Copyright QAI Laboratories, 2013 |