Directory of Listed Products
 
 

 

 
  BUILDING PRODUCTS LISTING PROGRAM  
  Class: Insulated Concrete Forms (ICF)  
       
  Customer: Amvic Incorporated  
  Location: 501 McNicoll Avenue, Toronto, Ontario, M2H 2E2 Canada  
       
  Listing No.: B1061-2  
 
  Effective Date: May 29, 2014  
Last Revised: No Revisions to Date
  Expires: N/A  
       
  Standards:

CAN/ULC S701 “Thermal Insulation, Polystyrene, Boards and Pipe Covering”. 

CAN/ULC S102.2 “Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies”. 

ASTM C578 “Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation”. 

ASTM E84 - “Standard Test Method for Surface Burning Characteristics of Building Materials”. 

UBC 26-3 “Room Fire Test Standard For Interior of Foam Plastic Systems”. 

CAN/ULC-S101 “Standard Methods of Fire Endurance Tests of Building Construction and Materials”. 

ASTM E119 / ANSI / UL 263 “Standard Test Methods for Fire Tests of Building Construction and Materials”.

UL 1715 “Standard for Fire Test of Interior Finish Material”.

 
       
  Product:

AmDECK Insulated Concrete Floor Systems

Amvic Insulated Concrete Forms (ICF)
 
       
  Label: Product is marked with labels supplied by Amvic Incorporated.  The label includes the manufacturer’s name, trademark, or other recognized symbol of identification, the product model designation, month and year of manufacture or equivalent, QAI logo with the ‘US’ and “C” identifier, and CAN/ULC S701 Type 2, ASTM C578 Type II, ASTM E84 FSI and SDI Rating, and CAN/ULC S102.2 FSI and SDI Rating.  Labels are applied to palletized finished products to ensure visibility on the jobsite.    
       
  Ratings:

The following outlines Amvic AmDeck In Floor Expanded Polystyrene Thermal Insulation Performance determined in accordance with the noted standards. 

Amvic AmDECK Properties per CAN/ULC S701

PROPERTY TYPE 2
Thermal Resistance
Minimum at 25 mm Thickness
(m2*oC/W)
0.70
Water Vapour Permeance Maximum at 25 mm Thickness
(Ng/Pa*s*m2)
200
Dimensional Stability Maximum Linear Change (%) 1.5
Flexural Strength Minimum
(kPa)
240
Water Absorption
By Volume Maximum (%)
4.0
Compressive Strength
 Minimum at 10% Deformation (kPa)
110
Limiting Oxygen Index Minimum
(%)
24

Amvic AmDECK Surface Burning Characteristics per CAN/ULC S102.2

AMDECK INSULATION DENSITY MAXIMUM THICKNESS FLAME SPREAD INDEX (FSI) SMOKE DEVELOPED INDEX (SDI)
Type 2 EPS Maximum 32 kg/m3 100 mm Maximum ≤ 210 ≥ 500

Amvic AmDECK Properties per ASTM C578

PROPERTY TYPE II

Compressive Strength

Minimum @ 10% Deformation (psi)
15.0

Thermal Resistance

Minimum @ 1 inch Thick (F*ft2*h/Btu)
4.0

Flexural Strength

Minimum  (psi)
35.0

Water Vapor Permeance

@ 1 inch Thickness Maximum (Perms)
3.5

Water Absorption

By Volume Maximum (%)
4.0

Dimensional Stability

Linear Change Maximum (%)
2.0

Oxygen Index

Minimum (%)
24.0
Density Minimum (lbs/ft3) 1.35

Amvic AmDECK Surface Burning Characteristics per ASTM E841
 
AMDECK INSULATION DENSITY MAXIMUM THICKNESS FLAME SPREAD INDEX (FSI) SMOKE DEVELOPED INDEX (SDI)
Type II Maximum 2.20 lbs/ft3 4.0 Inches Maximum ≤ 75 ≤ 450

1Ceiling Measurement Only. This measurement is conducted through determination of flame spread index and smoke developed index with the removal of any contribution of molten materials ignited on the floor of the tunnel assembly.

Amvic AmDECK UL 1715 Configuration

Meets requirements with ˝ inch thickness gypsum compliant with ASTM C1396 and listed with an approved agency when gypsum is installed in accordance with applicable code and secured to AmDECK.

The following outlines Amvic ICF test results determined in accordance with the noted standards.

Amvic ICF Type 2 Specifications per CAN/ULC S701

PROPERTY TYPE 2
Thermal Resistance
Minimum at 25 mm Thickness
(m2*oC/W)
0.70
Water Vapour Permeance Maximum at 25 mm Thickness
(Ng/Pa*s*m2)
200
Dimensional Stability Maximum Linear Change (%) 1.5
Flexural Strength Minimum
(kPa)
240
Water Absorption
By Volume Maximum (%)
4.0
Compressive Strength
 Minimum at 10% Deformation (kPa)
110
Limiting Oxygen Index Minimum
(%)
24

Amvic ICF Type II Specifications per ASTM C578

PROPERTY TYPE II

Compressive Strength

Minimum @ 10% Deformation (psi)
15.0

Thermal Resistance

Minimum @ 1 inch Thick (F*ft2*h/Btu)
4.0

Flexural Strength

Minimum  (psi)
35.0

Water Vapor Permeance

@ 1 inch Thickness Maximum (Perms)
3.5

Water Absorption

By Volume Maximum (%)
4.0

Dimensional Stability

Linear Change Maximum (%)
2.0

Oxygen Index

Minimum (%)
24.0
Density Minimum (lbs/ft3) 1.35

Amvic ICF Surface Burning Characteristics per CAN/ULC S102.2

AMVIC ICF COMPONENT DENSITY MAXIMUM THICKNESS FLAME SPREAD INDEX (FSI) SMOKE DEVELOPED INDEX (SDI)
Expanded Polystyrene
 (EPS Panel)
22 – 29 kg/m3 100 mm Maximum ≤ 210   ≥ 500

Amvic ICF Surface Burning Characteristics per ASTM E841

AMVIC ICF COMPONENT DENSITY MAXIMUM THICKNESS FLAME SPREAD INDEX (FSI) SMOKE DEVELOPED INDEX (SDI)
Expanded Polystyrene
 (EPS Panel)
1.35 – 1.80 lbs/ft3 4.0 Inches Maximum ≤ 75    ≤ 450

1Ceiling Measurement Only. This measurement is conducted through determination of flame spread index and smoke developed index with the removal of any contribution of molten materials ignited on the floor of the tunnel assembly. Amvic UBC 26-3 Configuration Meets requirements with ˝ inch thickness gypsum board complying with ASTM C1396, fastened with 1 5/8 inch length standard Type W drywall screws at 12 inch on center horizontally, and 16 inches on center vertically. Fasteners must be anchored into Amvic ICF web ties.



Note 1:  The allowable load for Amvic ICF 3 Hour Load Bearing Fire-Resistance-Rated Construction is to be determined by a registered design professional, or authority having jurisdiction in accordance with the applicable codes.

 
       
  Note:

Final acceptance of the product in the intended application is to be determined by the authority having jurisdiction. 

Product is to be installed in accordance with the manufacturer’s published installation instructions by qualified installing personnel.

 
 
 
 
  The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.

No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.

Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active.

Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.
 
   

Copyright QAI Laboratories, 2014