D.D. Builders Doors Supply Ltd.
Windows & Doors Listing Program
- D.D. Builders Doors Supply Ltd.
- Fenestration – Windows – Energy Performance
- Coquitlam, British Columbia
- W434-1 ED4
- W434-1 ED4
- September 18, 2009
- January 29, 2016
- N/A
-
CSA A440.2 “Fenestration Energy Performance”
-
Wood Casement Window, Wood Awning Window, Wood Picture Window, Wood Fixed Sash Window, Wood Single Hung Window
-
Each product is marked with the following content on a permanent label that is
readily visible after installation:
Manufacturer’s Name, Trademark or other recognized symbol of identification
QAI File Number (W434)
QAI logo with “c” indicator
“Evaluation for energy performance in accordance with CSA A440.2”
“Evalué pour la performance d’énergie en accord à la norme CSA A440.2” -
Wood Casement Window:
Product Model Code: U-Value (W/m2K) Energy Rating CS-4S60-SFT/4CL-ARG-SUPER 1.58 20 CS-4S60-SFT/4EA-HRD-ARG-SUPER 1.46 22 CS-4S60-SFT/4CL-ARG-SUPER-SDL 1.62 18 CS-4S60-SFT/4EA-HRD-ARG-SUPER-SDL 1.54 19 CS-4S60-SFT/4CL-ARG-SUPER-TDL 1.81 12 CS-4S60-SFT/4EA-HRD-ARG-SUPER-TDL 1.72 14 CS-4S60-SFT/4CL-ARG-SUPER-HTDL 1.85 11 CS-4S60-SFT/4EA-HRD-ARG-SUPER-HTDL 1.79 12 CS-4S60-SFT/4CL/4CL-ARG-SUPER 1.32 24 CS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER 1.20 27 CS-4S60-SFT/4CL/4CL-ARG-SUPER-SDL 1.35 22 CS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-SDL 1.25 24 CS-4S60-SFT/4CL/4CL-ARG-SUPER-TDL 1.50 18 CS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-TDL 1.42 20 CS-4S60-SFT/4CL/4CL-ARG-SUPER-HTDL 1.52 17 CS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-HTDL 1.45 18 Wood Awning Window:
Product Model Code: U-Value (W/m2K) Energy Rating AWN-4S60-SFT/4CL-ARG-SUPER 1.60 19 AWN-4S60-SFT/4EA-HRD-ARG-SUPER 1.50 20 AWN-4S60-SFT/4CL-ARG-SUPER-SDL 1.62 16 AWN-4S60-SFT/4EA-HRD-ARG-SUPER-SDL 1.55 17 AWN-4S60-SFT/4CL-ARG-SUPER-TDL 1.80 12 AWN-4S60-SFT/4EA-HRD-ARG-SUPER-TDL 1.72 13 AWN-4S60-SFT/4CL-ARG-SUPER-HTDL 1.84 10 AWN-4S60-SFT/4EA-HRD-ARG-SUPER-HTDL 1.77 11 AWN-4S60-SFT/4CL/4CL-ARG-SUPER 1.34 23 AWN-4S60-SFT/4CL/4EA-HRD-ARG-SUPER 1.22 25 AWN-4S60-SFT/4CL/4CL-ARG-SUPER-SDL 1.36 21 AWN-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-SDL 1.25 23 AWN-4S60-SFT/4CL/4CL-ARG-SUPER-TDL 1.50 17 AWN-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-TDL 1.41 19 AWN-4S60-SFT/4CL/4CL-ARG-SUPER-HTDL 1.52 16 AWN-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-HTDL 1.43 18 Wood Picture Window:
Product Model Code: U-Value (W/m2K) Energy
RatingPIC-4S60-SFT/4CL-ARG-SUPER 1.50 27 PIC-4S60-SFT/4EA-HRD-ARG-SUPER 1.25 31 PIC-4S60-SFT/4CL/4CL-ARG-SUPER 1.23 31 PIC-4S60-SFT/4CL/4EA-HRD-ARG-SUPER 1.03 35 Wood Fixed Sash Window:
Product Model Code: U-Value (W/m2K) Energy
RatingFS-4S60-SFT/4CL-ARG-SUPER 1.52 24 FS-4S60-SFT/4EA-HRD-ARG-SUPER 1.36 26 FS-4S60-SFT/4CL-ARG-SUPER-SDL 1.58 20 FS-4S60-SFT/4EA-HRD-ARG-SUPER-SDL 1.46 22 FS-4S60-SFT/4CL-ARG-SUPER-TDL 1.84 14 FS-4S60-SFT/4EA-HRD-ARG-SUPER-TDL 1.70 16 FS-4S60-SFT/4CL-ARG-SUPER-HTDL 1.89 11 FS-4S60-SFT/4EA-HRD-ARG-SUPER-HTDL 1.78 14 FS-4S60-SFT/4CL/4CL-ARG-SUPER 1.26 28 FS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER 1.11 31 FS-4S60-SFT/4CL/4CL-ARG-SUPER-SDL 1.31 25 FS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-SDL 1.18 27 FS-4S60-SFT/4CL/4CL-ARG-SUPER-TDL 1.52 19 FS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-TDL 1.40 22 FS-4S60-SFT/4CL/4CL-ARG-SUPER-HTDL 1.54 18 FS-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-HTDL 1.44 20 Wood Single Hung Window:
Product Model Code: U-Value (W/m2K) Energy
RatingSH-4S60-SFT/4CL-ARG-SUPER 1.63 20 SH-4S60-SFT/4EA-HRD-ARG-SUPER 1.45 23 SH-4S60-SFT/4CL-ARG-SUPER-SDL 1.68 17 SH-4S60-SFT/4EA-HRD-ARG-SUPER-SDL 1.55 19 SH-4S60-SFT/4CL-ARG-SUPER-TDL 1.92 10 SH-4S60-SFT/4EA-HRD-ARG-SUPER-TDL 1.78 13 SH-4S60-SFT/4CL-ARG-SUPER-HTDL 1.97 8 SH-4S60-SFT/4EA-HRD-ARG-SUPER-HTDL 1.85 11 SH-4S60-SFT/4CL/4CL-ARG-SUPER 1.41 23 SH-4S60-SFT/4CL/4EA-HRD-ARG-SUPER 1.26 26 SH-4S60-SFT/4CL/4CL-ARG-SUPER-SDL 1.45 21 SH-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-SDL 1.32 23 SH-4S60-SFT/4CL/4CL-ARG-SUPER-TDL 1.63 16 SH-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-TDL 1.52 17 SH-4S60-SFT/4CL/4CL-ARG-SUPER-HTDL 1.65 14 SH-4S60-SFT/4CL/4EA-HRD-ARG-SUPER-HTDL 1.55 16 -
Listed products meet the energy requirements of the standards listed above.
Windows are not intended for installation in storefronts, non-operable portions of curtain wall, fixed glazing cast into precast concrete panels, greenhouses, skylights
or sloped glazing. Test procedures are designed to test the performance of the test specimen only and are not necessarily used to test the performance of the installation, particularly the perimeter sealant joint and anchoring of the assembly.
Final acceptance of the product in a building is subject to approval by the authority having jurisdiction.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI. No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing. Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.