| BUILDING PRODUCTS LISTING PROGRAM | |||||||||||||
| Class: | Insulated Metal Wall Panels | ||||||||||||
| Customer: | Metl-Span, A Division of NCI Group, Inc. | ||||||||||||
| Location: | 1720 Lakepointe Drive, Lewisville, Texas | ||||||||||||
| Website: | http://www.metlspan.com/ | ||||||||||||
| Listing No.: | B1087-1 | ||||||||||||
| Effective Date: | October 23, 2015 | ||||||||||||
| Last Revised: | N/A | ||||||||||||
| Expires: | N/A | ||||||||||||
| Standards: |
ASTM E84 “Standard Test Method for
Surface Burning Characteristics of Building Materials”.
NFPA
286 “Standard Methods of
Fire Tests for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth”. |
||||||||||||
| Product: |
Metl-Span CleanSeam™ Wall and Ceiling Panels.
(Factory assembly of CF Insulated Metal Panels with Fiber
Reinforced Plastic (FRP) Interior Finish)
Metl-Span CleanSeam™ Joint Weld/Seam
(FRP joint weld & sealing material)
|
||||||||||||
| Label: | CleanSeam™ panels are marked with labels supplied by Metl-Span. The label includes the Manufacturer’s Name, Manufacturing Address, Product Name, Class A Flame Spread, QAI Logo with “US” indicator, and QAI Listing Number (B1087). | ||||||||||||
| Ratings: |
The following outlines
Metl-Span CleanSeam™ Wall and Ceiling Panels with CleanSeam™
Joint Weld/Seam connections performance determined in accordance
with the noted standards.
The ratings outlined in the tables below are achieved in
assemblies that are defined in the QAI Design Listings.
Metl-Span CleanSeam™ Wall
and Ceiling Panels with Joint Weld/Seam
The above assembly has been evaluated and found compliant for use
as Class A interior finish as outlined in the International Building
Code Section 803.1.1 Interior
Wall and Ceiling Finish Materials (or Section 803.1 on some code
editions), and complies with Section 803.12
Stability (or Section
803.3 on some code editions).
The above assembly has been evaluated and found compliant for use
as interior walls and ceilings in single
story buildings of Type I, II, III, and IV construction per Chapter
26 of the International Building Code for use without a code
prescribed thermal barrier per testing in accordance with Section
2603.9 Special Approval
(or Section 2306.10 on some code editions).
This assembly is not evaluated for fire-resistance rated wall
applications. |
||||||||||||
| Note: |
Final acceptance of the product in the intended application is to be
determined by the authority having jurisdiction. Product is to be installed in accordance with the QAI Design Listing and manufacturer’s published installation instructions by qualified installing personnel. |
||||||||||||
|
|
|||||||||||||
|
The materials, products or systems listed in this directory have
been qualified to bear the QAI Listing Mark under the conditions
stated with each Listing. Only those products bearing the QAI
Listing Mark are considered to be listed by QAI. No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing. Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request. |
|||||||||||||
|
Copyright QAI Laboratories, 2015 |
|||||||||||||