  Class: Fenestration – Wood Windows – Energy Performance  
       
  Customer: Vintage Woodworks, Inc.  
  Location: Victoria, BC  
       
  Listing No.: W424  
  Effective Date: April 24, 2009  
  Last Revised: July 16, 2013  
  Expires: N/A  
       
  Standards: CSA A440.2 “Energy Performance of Windows and Other Fenestration Systems”  
       
  Product: Wood Windows  
       
  Markings:

Each product is marked with the following content on a permanent label that is readily visible after installation:

  • Manufacturer’s Name, Trademark or other recognized symbol of identification

  • Date of Manufacture, production number or serial number

  • QAI File number (W446)

  • QAI logo with “c” indicator

          “Evaluation for energy performance in accordance with CSA A440.2” “Évalué pour la performance    

          d’énergie en accord à la norme CSA A440.2”

 
 
       
  Models:

Windows with glazing options as follows:

 

Product Model Code:

Traditional Double Hung

U-Value

(W/m2*K)

Energy Rating

TDH-CL(4)-air(13)SS-Lowe(4, e=0.035)-air(23)-Cl(4)

1.13

29

TDH-CL(4)-arg(13)SS-Lowe(4, e=0.035)-air(23)-Cl(4)

1.03

32

TDH-CL(4)-air(13)ST-Lowe(4, e=0.035)-air(23)-Cl(4)

1.16

29

TDH-CL(4)-arg(13)ST-Lowe(4, e=0.035)-air(23)-Cl(4)

1.06

31

 

 

 

Product Model Code:

Traditional Casement

U-Value

(W/m2*K)

Energy Rating

TCM-Cl(4)-air(13)SS-Lowe(4, e=0.035)

1.83

16

TCM-Cl(4)-arg(13)SS-Lowe(4, e=0.035)

1.68

19

TCM-Cl(4)-air(13)ST-Lowe(4, e=0.035)

1.92

14

TCM-Cl(4)-arg(13)ST-Lowe(4, e=0.035)

1.77

17

 

 

 

Product Model Code:

Original Casement

U-Value

(W/m2*K)

Energy Rating

OCM-Cl(4)-air(13)SS-Lowe(4, e=0.035)

1.87

13

OCM-Cl(4)-arg(13)SS-Lowe(4, e=0.035)

1.72

16

OCM-Cl(4)-air(13)ST-Lowe(4, e=0.035)

1.96

11

OCM-Cl(4)-arg(13)ST-Lowe(4, e=0.035)

1.81

14

 

Product Model Code:

Commercial Double-Hung Window

U-Value

(W/m2*K)

Energy Rating

Vintage-CDH-Cl(4)-Arg(12.7)-Cl(4)

2.23

15

Vintage-CDH-Cl(4)-Arg(12.7)-LE(4,e=0.035)

1.62

20

Vintage-CDH- LE(4,e=0.035)-Arg(12.7)-LE(4,e=0.147)

1.46

20

Vintage-CDH- LAM(6-.015)-Arg(12.7)-LAM(6-.015)

2.20

15

 

 
 
       
  Note: Windows are not intended for installation in storefronts, non-operable portions of curtain wall, fixed glazing cast into precast concrete panels, greenhouses, skylights or sloped glazing. Test procedures are designed to test the performance of the test specimen only and are not necessarily used to test the performance of the installation, particularly the perimeter sealant joint and anchoring of the assembly.  
 
 
 