Pacific Insulation Products
Building Products Listing Program
- Pacific Insulation Products
- Insulated Foil Faced Panels
- Sultan, WA
- B1103-1
- B1103-1
- July 1, 2018
- June 25, 2021
- N/A
-
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials.
UL 1715 Fire Test of Interior Finish Material.
CAN/ULC S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.
CAN/ULC S138 Standard Method of Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration. -
R-Seal Insulated Wall and Roof Panels
-
Each panel is marked with a permanent label containing the following information:
a) Address, including city and country of manufacture
b) Product Name
c) Date of Manufacture
d) Job Number
e) QAI Certification logo and listing number (B1103)
f) Flame Spread Index / Smoke Developed Index (FSI < 25 / SDI < 450 ASTM E84, FSI < 25 / SDI < 150 ULC S102)
g) QAI logo shown here: -
Pacific Insulation Products R-Seal panels have surface burning characteristics
determined in accordance with ASTM E84:Model(s) Flame Spread Index Smoke Developed Index Thickness Max. (Inches) Density Max. (lbs/ft3) R-Seal with skin ≤ 25 ≤ 450 5 2.5 R-Seal foam core with skins removed ≤ 25 ≤ 450 5 2.5 Pacific Insulation Products R-Seal panels have surface burning characteristics
determined in accordance with CAN/ULC S102:Model(s) Flame Spread Index Smoke Developed Index Thickness Max. (mm) Density Max. (kg/m3) R-Seal with skin and joint evaluated. ≤ 25 ≤ 500 127 40 R-Seal foam core with skins removed ≤ 25 ≤ 500 127 40 Pacific Insulation Products R-Seal panels evaluated to UL 1715:
Model(s) Density (lbs/ft3) Thickness Max. (Inches) Application R-Seal 2.5 Wall: 3
Ceiling: 5Wall and ceiling panels are
mechanically attached to
underlying structure with screws
including washers of 1’’ diameter,
with screws anchored into
underlying structure. Ceiling to
wall and corners are to be finished
with 4’’ steel angle mechanically
secured at 12’’ on center. Panel
placement to ensure tight joints,
per manufacturer’s installation
instructions. Joint sealant and
aluminum foil tape along the panel
edges is optional.Pacific Insulation Products R-Seal panels evaluated to CAN/ULC S138:
Model(s) Density (lbs/ft3) Thickness Max. (Inches) Application R-Seal 2.5 Wall: 3
Ceiling: 5Wall and ceiling panels are
mechanically attached to
underlying structure with screws
including washers of 1’’ diameter,
with screws anchored into
underlying structure. Ceiling to
wall and corners are to be finished
with 4’’ steel angle mechanically
secured at 12’’ on center. Panel
placement to ensure tight joints,
per manufacturer’s installation
instructions. Joint sealant and
aluminum foil tape along the panel
edges is optional.
Installation is to include 155oF
(68oC) activation temperature
pendant style listed sprinklers.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.