Firestable® Insulation Company
Building Products Listing Program
- Firestable® Insulation Company
- Polyurethane Foam Insulation
- Essex, CT
- B1134-1
- B1134-1
- May 30, 2022
- October 30, 2024
- N/A
-
ASTM E84-23d
Standard Test Method for Surface Burning Characteristics of Building Materials.
UL 723-18
Standard for Test for Surface Burning Characteristics of Building Materials.
NFPA 255- 2006
Standard Method of Test of Surface Burning Characteristics of Building Materials.
ASTM E2768-11
Standard Test method for Extended Duration Surface Burning Characteristics of Building Materials (30 min Tunnel Test).
NFPA 275-2022
Standard Method of Fire Tests for the Evaluation of Thermal Barriers.
UL 1715-2017
Fire Test of Interior Finish Materials.
2021 / 2018
International Building Code Section 803.14 Stability.
2015
International Building Code Section 803.12 Stability.
-
Firestable® FS 2.0 Spray-Applied Foam.
-
Description:
Firestable® FS 2.0 is a spray-applied polyurethane foam used as a thermal barrier for the protection of foam plastics described below. Firestable® is available in the following colors:
•Cloud White.
•Charcoal.Markings:
Firestable® FS 2.0 Component A and Component B drums bear a label with markings including the information outlined below:
•Manufacturer’s Name
•Product name – Firestable® FS 2.0
•ASTM E84 Class A: Flame Spread ≤ 25 / Smoke Development ≤ 450 @ 4’’
•Traceability Code (Lot Number)
•QAI Listing Number (B1134) and Certification Logo shown: -
Models / Ratings:
The following outlines Firestable® FS 2.0 Spray-Applied Foam results determined in accordance with ASTM E84, UL 723, and ANSI/NFPA 255:
PRODUCT
FLAME SPREAD INDEX (FSI)
SMOKE DEVELOPED INDEX (SDI)
THICKNESS MAX. (inches)
DENSITY
MAX (lbs/ft3)
Firestable® FS 2.0
≤ 25
≤ 450
4
2.8
The following outlines Firestable® FS 2.0 Spray-Applied Foam results determined in accordance with ASTM E2768 / ASTM E84 Continued for 20 Minutes:
PRODUCT
FLAME SPREAD INDEX (FSI
SIGNIFCANT PROGRESSIVE COMBUSTION
MAX FLAME FRONT (ft)
THICKNESS MAX. (inches)
DENSITY
MAX (lbs/ft3)
Firestable® FS 2.0
≤ 25
No
≤ 10.5
4
2.8
The following outlines Firestable® FS 2.0 spray-applied foam approved installation as a thermal barrier for protection of foam plastics in accordance with NFPA 275:
INSTALLED FIRESTABLE® FS 2.0 ≥ 2.5 INCHES THICKESS, 2.5 lbs/ft3 DENSITY
THERMOPLASTIC INSULATION
THERMOSETTING INSULATION
DENSITY (lbs/ft3)
MAX. THICKNESS (inches)
MAX. DENSITY (lbs/ft3)
MAX. THICKNESS (inches)
1.0
5-1/2
3.0
6-1/2
1.5
3-1/4
2.0
2.5
2.5
2
3.0
1-3/4
Firestable® FS 2.0 spray-applied foam has met 2021 / 2018 International Building Code Section 803.14 Stability, 2015 International Building Code Section 803.12 Stability when applied to thermoplastic foam plastics, thermosetting foam plastics, cement board, metal and gypsum-based substrates.
The following outlines Firestable® FS 2.0 results determined in accordance with UL 17151:
Note 1: Testing to UL 1715 was conducted following 2021 / 2018 / 2015 International Building Code Section 2603.9 Special Approval evaluation based on full scale testing of an end-use configuration.
PRODUCT
BASE FOAM TYPE
BASE FOAM THICKNESS
(inches)
BASE FOAM DENSITY
(lbs/ft3)
INSTALLATION
Firestable® FS 2.0
A) IBC 2603.9
(Alternate)
No Base Foam
Firestable FS 2.0 at 2.5 lbs/ft3 nominal density target from 1’’ to 9’’ installed thickness.
Ensure the substrate is dry and clean of debris and dust. Firestable FS 2.0 is applied in a single pass up to 2.5 inches thickness, at 2.5 lbs/ft3 target density (2.3 – 2.8 lbs/ft3 required). FS 2.0 is applied to ensure a continuous unbroken surface across walls and ceilings. Installation of Firestable FS 2.0 to be done at ambient temperatures of 30 – 100oF where temperatures are > 5oF above the dew point to ensure bond to substrate.
Firestable® FS 2.0
B) IBC 2603.4
(Equivalent)
Firestable FS 2.0 at 2.5 lbs/ft3 nominal density target at ≥ 2.5 inches where installed per NFPA 275 above.
Firestable® FS 2.0
IBC 2603.4
(Equivalent)
Thermoplastic
See NFPA 275 Above
Ensure base foam is dry and clean of debris and dust. Firestable FS 2.0 is applied in a single pass to minimum 2.5 inches thickness, at 2.5 lbs/ft3 target density (2.3 – 2.8 lbs/ft3 required). FS 2.0 is applied to ensure a continuous unbroken surface across walls and ceilings to ensure underlying foam protection with no voids or gaps present. Installation of Firestable FS 2.0 to be done at ambient temperatures of 30 – 100oF where temperatures are > 5oF above the dew point to ensure bond to base foam layer.
Firestable® FS 2.0
IBC 2603.4
(Equivalent)
Thermosetting
See NFPA 275 Above
First pass of thermosetting foam base layer is applied to maximum thickness and density described in NFPA 275 above. The base layer is to be allowed to condition to ambient temperature and confirmed to be clean and dry prior to application of Firestable FS 2.0. Following, at minimum a single pass of Firestable FS 2.0 is to be applied at 2.5 inches thickness, at 2.5 lbs/ft3 target density (2.3 – 2.8 lbs/ft3 installed required). FS 2.0 is applied to ensure a continuous unbroken surface across walls and ceilings to ensure underlying foam protection with no voids or gaps present. Installation of Firestable FS 2.0 to be done at ambient temperatures of done at ambient temperatures of 30 – 100oF where temperatures are > 5oF above the dew point to ensure bond to base foam layer.
For application the manufacturers installations instructions must be followed, foam MUST be cured and cooled to ambient conditions, all surface preparation should be carried out in accordance with good application practices. Firestable® FS 2.0 should be installed by qualified contractors to ensure product performance.
Firestable FS 2.0 is to be installed at target thicknesses noted, in the density tolerances shown for use as a thermal barrier.
Final acceptance of the product in the intended application is to be determined by the authority having jurisdiction.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.