ISOLOC Insulated Panel & Door Systems
Building Products Listing Program
- ISOLOC Insulated Panel & Door Systems
- Insulated Metal Panels
- Calgary, AB, Canada
- B1161-1
- B1161-1 Edition 1
- April 15, 2026
- April 15, 2026
- N/A
-
CAN/ULC S102-19
Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.
CAN/ULC S127-14
Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials
CAN/ULC S138-06
Standard Method of Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration.
ASTM C518-21
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus -
ISOLOC Camlock Insulated Metal Panels (IMP)
-
Each panel is marked with a permanent label containing the following information:
a) Manufacturer’s name or recognized trademark
b) Product name
c) Date of manufacture
d) QAI file number: B1161
e) CAN/ULC S102 Flame Spread Index and Smoke Developed Index
f) CAN/ULC S138 compliant
g) QAI logo shown here: -
ISOLOC Camlock IMP have the following performance properties when evaluated per CAN/ULC S102:
Model(s)
Flame Spread Index
Smoke Developed Index
Thickness Maximum
mm (inches)
Density Max. kg/m3 (lbs/ft3)
Camlock insulated metal panels
(w/o Steel Skin)
≤ 5001
≤1000
127
(5)
40
(2.5)
Camlock insulated metal panels
(with Steel Skin including treated panel joint2)
≤ 50
≤1000
127
(5)
40
(2.5)
Note 1: Flame spread determined in accordance with CAN/ULC S127 as required by CAN/ULC S102 for thermosetting charring foam.
Note 2: Joint treated with ADSeal Production 4550 sealant.
ISOLOC Camlock IMP have the following rating determined in accordance with CAN/ULC-S138:
Design Listing
Model(s)
CAN/ULC-S1381
Camlock IMP maximum 127 mm (5 inches) thickness
Joints treated with ADSeal Production
4550 silicone sealant and camlocks covered with plastic caps.
Room equipped with standard response 68°C (155°F) activation temperature, pendant style listed sprinklers.
ISOLOC Camlock IMP have the following thermal resistivity and minimum thickness required for compliance with National Resources Canada (NRCan) Energy Efficiency Regulation requirements when evaluated per ASTM C518 for applications noted1:
Application
Thermal Resistivity
m·K/W (hr·ft2· oF / Btu·in)
Required Minimum Thickness
mm (inch)
Walk-In Cooler Walls and Ceilings
Mean Temp at 12.8oC (55oF)
47.0 (6.8)
102 (4)
Walk-In Cooler Floors
Mean Temp at 12.8oC (55oF)
105 (4.1)
Note 1: Evaluation was conducted in accordance with 10 C.F.R. Appendix B to Subpart R, Part 431 of Title 431 of Title 10 for R-Value of walk-in panels.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.






USA
Canada
Europe
China
S Korea