Mobilfab Inc.
Factory Built Structures Listing Program
- Mobilfab Inc.
- Relocatable Commercial Industrial Structures
- Pointe-Aux-Trembles, QC
- REC610-1
- REC610-1
- July 12, 2013
- May 31, 2017
- N/A
-
CSA A277 “Procedure for Certification of Prefabricated Buildings, Modules, and Panels”
CSA C22.1-12 “Canadian Electrical Code, Part I, Safety Standard for Electrical Installations”
Alberta Building Code 2006 (Part 9 & 10)
National Building Code of Canada 2010 (Part 9)
National Plumbing Code of Canada 2010Note: Unless otherwise specified, the standards/Code noted are the most current versions in effect.
-
Relocatable Commercial Industrial Structures
-
All markings must be permanent and visible after installation.
1. The specification nameplate (item 1068, 8-1/2” x 14” in size) is located in close proximity to the electrical panel and includes:
Manufacturer’s Name and Address
Date of Manufacture
Model Serial Number or Product Code
Foundation Type (Perimeter Foundation Wall or Piers)
Floor live Load
Specified Snow Load (1/50)
Seismic Response Sa (0.2)
Hourly Wind Pressure (1/50)
Envelope Effective Thermal Resistance
Windows/Doors/Skylights Thermal Characteristics
Outside Design Temperature (Heal Loss or Heat Gain)
Factory Installed Appliances
Site Installed Components, Assemblies, and Systems
Electrical Systems Voltage, Frequency, and Amperage2. QAI label with ‘C’ identifier (Item 1093) – Relocatable Commercial Industrial Structures – Alberta Plumbing and Gas Compliance Label (Alberta Part 10 Program)
3. QAI Label with ‘C’ identifier (Item 1094) – Relocatable Commercial Industrial Structures – Alberta Electrical Compliance Label (Alberta Part 10 Program)
4. QAI Label with ‘C’ identifier (Item 1095) – Relocatable Commercial Industrial Structures – A277 Compliance Label
5. QAI logo shown here:
Other Markings as required by the relevant codes.
The QAI label and specification nameplate are available from QAI and must be applied at the factory.
-
Relocatable Commercial Industrial Structures are used for Major Occupancy classified as Group C (Residential) and Group D (Business and Personal Services occupancies). Buildings with sleeping accommodation have a building area not exceeding 600m2 and buildings without sleeping accommodation have a building area not exceeding 1200m2.
Structures described above typically include but are not limited to construction camp facilities, such as dormitories, portable washroom trailers, dining trailers, office space and other similar commercial or industrial buildings. These buildings are comprised of single or multiple modules in a single storey configuration and without sprinkler systems.
This listing does not include vehicular lighting or break wiring systems.Structural:
Conventional Wood Frame Construction within the limitations of Part 9 of the National Building Code.Electrical Ratings:
120/240 VAC, 60Hz, 600A max.Heating/Ventilation:
Exterior wall mounted forced air furnaces. Units to be Electric only. Systems may be equipped with air conditioning.Plumbing:
Conventional drainage and venting systems to a maximum of 240 hydraulic fixture units.
Gas Systems:
None.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.