AMC Foam Technologies, Inc.
Building Products Listing Program
- AMC Foam Technologies, Inc.
- Thermal Insulation
- Headingley, Manitoba
- B1088-1
- B1088-1, Edition 3
- March 2, 2016
- December 16, 2024
- N/A
-
CAN/ULC S701.1:2017
Standard for Thermal Insulation, Polystyrene Boards.
ASTM C578-2023
Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation.
ASTM D1621-2016
Standard Test Method for Compressive Properties of Rigid Cellular Plastics.
ASTM E84-2021a
Standard Test Method for Surface Burning Characteristics of Building Materials.
CAN/ULC S102.2-2018
Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies
-
Expanded Polystyrene Foam Plastic Insulation Products as outlined below:
• STYROVOID® (LD) Low Density Compression Board
• STYROBAR® 16 Rigid Insulation Board
• STYROBAR® 22 Rigid Insulation Board
• STYROBAR® 28 Rigid Insulation Board
• STYROBAR® 16(+) Rigid Insulation Board
• STYROBAR® 22(+) Rigid Insulation Board
• STYROBAR® 28(+) Rigid Insulation Board
• STYROBAR® HS-40 Rigid High Compression Resistance Board -
The following outlines AMC Foam Technologies, Inc. product’s Thermal Insulation Performance determined in accordance with the noted standards.
AMC Foam Technologies Inc. STYROBAR® EPS insulation products specifications per CAN/ULC S701.1.
PROPERTY
STYROBAR® 16, STYROBAR® 16(+)
STYROBAR® 22, STYROBAR® 22(+)
STYROBAR® 28, STYROBAR® 28(+)
STYROBAR® HS-40
TYPE 1
TYPE 2
TYPE 3
TYPE 3
Thermal Resistance
Minimum at 25 mm Thickness
(m2*oC/W)
0.65
0.70
0.74
0.74
Water Vapour Permeance Maximum at 25 mm Thickness
(Ng/Pa*s*m2)
300
200
130
130
Dimensional Stability Maximum Linear Change (%)
1.5
1.5
1.5
1.5
Flexural Strength Minimum
(kPa)
170
240
300
300
Water Absorption
By Volume Maximum (%)
6.0
4.0
2.0
2.0
Compressive Strength
Minimum at 10% Deformation (kPa)
70
110
140
2761
Limiting Oxygen Index Minimum
(%)
24
24
24
24
Note1: STYROBAR® HS-40 has been evaluated and shown to have a compressive resistance at 10% deformation of 276 kPa (40 psi) as outlined in ASTM C578 XIV compliance noted below when evaluated to ASTM D1621.
AMC Foam Technologies Inc. STYROVOID® (LD) products specifications evaluated.
PROPERTY
STYROVOID® LD
NON-CLASSIFIED TYPE2
Compressive Strength
Minimum @ 10% Deformation
70.0 kPa
10.0 psi
Density Minimum
11.2 kg/m3
0.70 lbs/ft3
Note2: STYROVOID® LD products have a compressive resistance of 70 kPa (10.0 psi) at 10% deformation when evaluated to ASTM D1621 when molded at the minimum density noted.
AMC Foam Technologies Inc. insulation products surface burning characteristics determined in accordance with CAN/ULC S102.2.
AMC FOAM TECHNOLOGIES
INSULATION3
DENSITY
MAXIMUM THICKNESS
FLAME SPREAD INDEX (FSI)
SMOKE DEVELOPED INDEX (SDI)
STYROVOID® (LD)
STYROBAR® 16, STYROBAR® 22, STYROBAR® 28
STYROBAR® 16(+), STYROBAR® 22(+), STYROBAR® 28(+)
Maximum 32 kg/m3
100 mm Maximum
≤ 230
≥ 500
Note3: STYROBAR® HS-40 products are molded at minimum 38 kg/m3 density. As such, these products are not classified for surface burning characteristics noted and are not eligible for use as interior insulation products.
AMC Foam Technologies Inc. STYROBAR® insulation products specifications per ASTM C578.
PROPERTY
STYROBAR® 16, STYROBAR® 16(+)
STYROBAR® 22, STYROBAR® 22(+)
STYROBAR® 28, STYROBAR® 28(+)
STYROBAR® HS-40
TYPE I
TYPE II
TYPE IX
TYPE XIV
Compressive Strength
Minimum @ 10% Deformation (psi)
13.0
15.0
25.0
40.0
Thermal Resistance
Minimum @ 1 inch Thick (F*ft2*h/Btu)
3.6
4.0
4.2
4.2
Flexural Strength
Minimum (psi)
30.0
35.0
50.0
60.0
Water Vapor Permeance
@ 1 inch Thickness Maximum (Perms)
5.0
3.5
2.5
2.5
Water Absorption
By Volume Maximum (%)
4.0
3.0
2.0
2.0
Dimensional Stability
Linear Change Maximum (%)
2.0
2.0
2.0
2.0
Oxygen Index
Minimum (%)
24.0
24.0
24.0
24.0
Density Minimum (lbs/ft3)
1.15
1.35
1.80
2.40
AMC Foam Technologies Inc. insulation products surface burning characteristics determined in accordance with ASTM E84
AMC
INSULATION
DENSITY
MAXIMUM THICKNESS
FLAME SPREAD INDEX (FSI)
SMOKE DEVELOPED INDEX (SDI)
STYROVOID® (LD)
STYROBAR® 16, STYROBAR® 22, STYROBAR® 28
STYROBAR® 16(+), STYROBAR® 22(+), STYROBAR® 28(+)
Maximum 2.20 lbs/ft3
4.0 Inches Maximum
≤ 25
≤ 450
Note4: STYROBAR® HS-40 products are molded at minimum 2.40 lbs/ft3 density. As such, these products are not classified for surface burning characteristics noted and are not eligible for use as interior insulation products.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.