Cool Master Refrigeration Inc.
Building Products Listing Program
- Cool Master Refrigeration Inc.
- Walk-In Cooler and Freezer Door Assemblies
- Tottenham, Ontario Canada
- B1158-2
- B1158-1, Edition 4
- October 16, 2026
- October 16, 2026
- N/A
-
ASTM C518-21
“Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus”.NFRC 102-2020
“Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems”. -
Cool Master Door Assemblies for walk-in coolers and freezers of the following types:
•Cool Master Single Swing Panel Door
-
Cool Master Walk-In Cooler and Freezer Door Assemblies listed below have the following thermal resistivity and daily energy consumption required for compliance with National Resources Canada (NRCan) Energy Efficiency Regulation requirements when evaluated per ASTM C518 and NFRC 102-2020 for applications noted.
Table 1 – Results for Single Swing Panel Door Assembly – Cooler Application
Frame Type
Overall Thickness
Assembly Size
Door Size
Thermal Resistivity
Daily Energy Consumption
Camlock Panel
102 mm (4-in)
1.20 m x 2.24 m (47-1/4-in x 88-in)
0.87 m x 1.98 m (34-in x 78-in)
5.08 K·m2/W (28.8 ft2·°F·h/Btu)
1.20 kWh/day (4.08 kBTU/day)
1.25 m x 2.24 m (49-1/4-in x 88-in)
0.91 m x 1.98 m (36-in x 78-in)
5.08 K·m2/W (28.8 ft2·°F·h/Btu)
1.20 kWh/day (4.10 kBTU/day)
Table 2 – Results for Single Swing Panel Door Assembly – Freezer Application
Frame Type
Overall Thickness
Frame Config.
Assembly Size
Door Size
Thermal Resistivity
Daily Energy Consumption
Camlock Panel
102 mm (4-in)
Three Sided
1.20 m x 2.24 m (47-1/4-in x 88-in)
0.87 m x 1.98 m (34-in x 78-in)
5.71 K·m2/W (32.4 ft2·°F·h/Btu)
7.54 kWh/day (25.7 kBTU/day)
1.25 m x 2.24 m (49-1/4-in x 88-in)
0.91 m x 1.98 m (36-in x 78-in)
5.71 K·m2/W (32.4 ft2·°F·h/Btu)
7.50 kWh/day (25.6 kBTU/day)
Four Sided
1.20 m x 2.24 m (47-1/4-in x 88-in)
0.87 m x 1.98 m (34-in x 78-in)
5.71 K·m2/W (32.4 ft2·°F·h/Btu)
7.80 kWh/day (26.6 kBTU/day)
1.25 m x 2.24 m (49-1/4-in x 88-in)
0.91 m x 1.98 m (36-in x 78-in)
5.71 K·m2/W (32.4 ft2·°F·h/Btu)
7.70 kWh/day (26.3 kBTU/day)
Note:
Evaluation was conducted in accordance with 10 CFR-2017, Part 431, Subpart R, Appendix A and Appendix B
Products must be installed with the manufacturer’s published installation instructions and in accordance with the building codes recognized by the authority having jurisdiction.
Listed manufacturers are subject to on-going inspections by QAI to ensure that the products outlined above remains as it is listed.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.





USA
Canada
Europe
China
S Korea