Crown Door Corp.
Windows & Doors Listing Program
- Crown Door Corp.
- Fire Door and Frame Machiner
- Abbotsford, BC
- F409-1
- F409-1
- June 15, 2012
- February 14, 2013
- N/A
-
CAN/ULC-S104 (2010) Standard Method for Fire Tests of Door Assemblies UL10 (b) (2008) Fire Tests of Doors Assemblies UL10 (c) (2001) Fire Tests of Doors Assemblies (Category “B”) NFPA-252 (2008) Standard Methods of Fire Tests of Door Assemblies UBC-7-2 (1994) Uniform Building Code UBC-7-2 (1997) Uniform Building Code ASTM E2074 (2004) Standard Test Method for Fire Tests of Door Assemblies, Including Positive
Pressure Testing of Side-Hinged and Pivoted Swinging Door Assemblies -
Fire Door and Frame Machining
-
Marking:
Each container of the subject product, as delivered to the customer, is suitably marked using Permanent label stock with
permanent adhesive with the following:
1. QAI logo with ‘c’ and ‘us’ indicator
2. Manufacturers name or trademark
3. City and state of manufacture
4. Model/Listing number or product description
5. QAI file number (F409)
6. Traceability Information: date of manufacture or serial number
7. Standards: See above
8. Applicable Ratings: See belowMarking Method:
Permanent label stock fastened with pins or permanent adhesive.Marking Details:
Each product is marked with a permanent label that is readily visible after installation within the top 1/3 of the hinge stile:
For wood edged doors:
The certification label shall be applied with screw-type nails (min. 5/8” (15.9 mm), or minimum 18 gauge staple with ¼” (6.4 mm) crown and 5/8” (15.9 mm) length). Two staples (one at each end of the label) shall be applied parallel to the edge of the label.
For steel edged doors:
The certification label shall be applied to the hinge edge of the door with either 1/8” (3.2 mm) diameter rivets or talk welds or adhesive
Exception 1:
When a continuous hinge is applied to the assembly, the certification label shall be attached to the top of the door.
Exception 2:
When a continuous hinge is applied to the assembly and a concealed closer arm is used the certification label shall be attached within the top 1/3 of the door to the face of the door near the hinge edge of the door. -
Approved Door Slabs for Machining:
(Refer to appendix A of F409-1 – Evaluation Report for Slab Details)20-Minute Wood/Insulation Core Door Slabs:
Neutral Pressure:
(UBC 7-2 (1994), UL 10b (2008), NFPA 252 (2008), ASTM E2074 (2004) & CAN/ULC S104)Manu. Swing Type Panel Type Skin Core Thickness Max. Size Width Height Jeld-Wen Single Profiled or
FlushHardboard Wood Particleboard 1.69” 36” 80” Jeld-Wen Single Profiled or
FlushWood 1.75” 36” 96” Jeld-Wen Double Profiled or
FlushWood 1.75” 72” 96” Jeld-Wen Single Profiled or
Flush1/16″
FiberglassCelotex 18 pcf 1.75” 36” 80” Jeld-Wen Single Profiled or
Flush“Environ” 27 pcf 1.75” 36” 80” Masonite Single Profiled or
FlushHardboard Wood Particleboard 1.75” 36” 96” Masonite Double Profiled or
FlushHardboard Wood Particleboard 1.75” 72” 84” Positive Pressure:
(UBC 7-2 (1997), UL 10c (2001) Category “B”Manu. Swing Type Panel Type Skin Core Thickness Max. Size Width Height Jeld-Wen Single Profiled or
FlushWood 1.75” 36” 96” Jeld-Wen Double Profiled or
FlushWood 1.75” 72” 96” Jeld-Wen Single Profiled or
Flush1/16″
FiberglassCelotex 18 pcf 1.75” 36” 80” Masonite Single Profiled or
FlushHardboard Wood Particleboard 1.75” 36” 96” Masonite Double Profiled or
FlushHardboard Wood Particleboard 1.75” 72” 84” 20-Minute Steel-Faced/Foam Core/Wood Edged Door Slabs:
Neutral Pressure:
(UBC 7-2 (1994), UL 10b (2008), NFPA 252 (2008), ASTM E2074 (2004) & CAN/ULC S104)Manu. Swing Type Panel Type Skin Core Thickness Maximum Size Width Height Jeld-Wen Single Flush Steel Foam 1.75” 36” 80” Jeld-Wen Double Profiled or
Flush24 ga Steel 1.0 pcf Expanded
Polystyrene Foam1.75” 36” 80” Masonite Single Profiled or
FlushSteel Polyurethane 1.75” 36” 84” Positive Pressure:
(UBC 7-2 (1997), UL 10c (2001) Category “B”Manu. Swing Type Panel Type Skin Core Thickness Max. Size Width Height Jeld-Wen Single Flush Steel Foam 1.75” 36” 80” Jeld-Wen Double Profiled or
Flush24 ga Steel 1.0 pcf Expanded
Polystyrene Foam1.75” 36” 80” Masonite Single Profiled or
FlushSteel Polyurethane 1.75” 36” 84” 45-Minute Hollow Metal with EPS Foam Insulation Fire Door Slabs:
Neutral Pressure:
(UBC 7-2 (1994), UL 10b (2008), NFPA 252 (2008), ASTM E2074 (2004) & CAN/ULC S104)Manu. Swing Type Panel Type Skin Core Thickness Max. Slab Size Width Height Artek Double Flush 18 Gauge
SteelExpanded Polystyrene
(EPS)1.75” 48” 96” 90-Minute Hollow Metal with EPS Foam Insulation Fire Door Slabs:
Neutral Pressure:
(UBC 7-2 (1994), UL 10b (2008), NFPA 252 (2008), ASTM E2074 (2004) & CAN/ULC S104)Manu. Swing Type Panel Type Skin Core Thickness Max. Slab Size Width Height Artek Double Flush 18 Gauge Steel Expanded Polystyrene
(EPS)1.75” 48” 96” Approved Door Frame Details for Machining:
Steel or Wood Frames that meet ANSI A155.1/UL 63/ULC S105 or as per the following:
Neutral Pressure Wood Frames:
(UBC 7-2 (1994), UL 10b (2008), NFPA 252 (2008), ASTM E2074 (2004) & CAN/ULC S104)Maximum Sizes:
20 Minute:Single Swing See Table Above Pair See Table Above Minimum Jamb Depth 3-3/4” 45/90 Minute:
Single Swing See Table Above Pair See Table Above Minimum Jamb Depth 3-1/2” Frame Cross Section Dimensions:
Wood Frame:
Minimum Stop Depth 1/2” Minimum Rabbet 1-13/16” (Non-Kerfed Frames) 1-15/16” (Kerfed Frames) Minimum Soffit 1-13/16” Minimum Face Width 11/16” (Door Side) 1-3/16” (Soffit Side) Maximum Kerf for Weather-stripping 1/8” x 1/2” Note: Kerf is optional all labeled frames Expandable Artek Steel Frame:
Rebate Width: 96” Rebate Height: 96” Metal Gauge: 18 gauge Satin Coat Galvanized Steel Face Length: 2” Back Bends: 1/2” Stop Height: 5/8” Material:
20 minute Wood Frames:
Solid Wood (Grade 1 or better) with a minimum specific gravity of 0.36 at 12% moisture content (Sugar Pine)45/90 minute Artek Steel Frames:
Hinge Reinforcements: 10 gauge, 9-1/4” x 1-1/4” Closer Reinforcement: 16 gauge, 12” x 1-1/2” Corner Connection Tabs: 20 gauge, spot welded to the jambs Slides: 16 gauge stamped interlocking sliders, welded to frame with four spot welds, four sliders per jamb for headers, 4-1/2” from ends and 30” on centers. Anchoring: Screws are installed in the prepared holes in the face of the frame (four per jamb and for the header) Positive Pressure Wood Frames:
(UBC 7-2 (1997), UL 10c (2001) Category “B”Maximum Sizes:
Single Swing 4’0” wide by 9’0” high Pair 8’0” wide by 9’0” high Minimum Jamb Depth 3-3/4” Frame Cross Section Dimensions:
Minimum Stop Depth 1/2” Minimum Rabbet 1-13/16” (Non-Kerfed Frames) 1-15/16” (Kerfed Frames) Minimum Soffit 1-13/16” Minimum Face Width 11/16” (Door Side) 1-3/16” (Soffit Side) Maximum Kerf for Weather-stripping 1/8” x 1/2” Note: Kerf is optional all labeled frames Material:
Frames up to 3’6” wide by 8’0” high:
Solid Wood (Grade 1 or better) with a minimum specific gravity of 0.36 at 12% moisture content (Sugar Pine)
Frames larger than 4’6” wide by 8’0” high:
Solid Wood (Grade 1 or better) with a minimum specific gravity of 0.47 at 12% moisture content (Sugar Pine)Please refer to the listing document link at the top of the page for Door & Frame Components
Installation Instructions:
Installation instructions shall be provided to the installer by the licensed machiner. The instructions may be attached to the door with stapled or with adhesive-backed label (refer also to “labeling”)The instructions shall contain at least the following information:
- Trimming for height may be done on the bottom rail only (per NFPA 80, maximum trim of 3/4”/19.0mm allowed
on-site). - Trimming for height is not allowed for Steel Doors.
- Surface mounted hardware must be attached with throughbolts unless interior blocking is provided.
- A maximum 1/8” (3.2mm) clearance between the frame and the door is allowed.
- A maximum 1/8” (3.2mm) clearance between the top leaf and the bottom leaf of dutch door, or transom and door, or between leaves of pairs, is allowed
- Trimming for height may be done on the bottom rail only (per NFPA 80, maximum trim of 3/4”/19.0mm allowed
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.