Hamilton Security
Windows & Doors Listing Program
- Hamilton Security
- Fire Doors
- Milford, Ohio
- F477-1
- F477-1
- September 15, 2023
- September 15, 2023
- N/A
-
UL 10B Fire Tests of Door Assemblies
UL 10C Positive Pressure Fire Tests of Door Assemblies
NFPA 252 Standard Methods of Fire Tests of Door Assemblies -
Hamilton Security 90-Minute Vault Fire-Resistance Rated Door and Frame Assemblies
-
90-MINUTE FIRE-RESISTANCE RATED VAULT DOOR AND FRAME ASSEMBLIES OF THE FOLLOWING SPECIFICATIONS:
Model
Dimensions
Rebar Reinforcement
Shell Material
Overall Thickness
Opening
Door
Frame
Width
Height
HUD-1-RS3680
4”
(102 mm)6.63”
(168 mm)3’0’’
(914 mm)
7’8’’
(2337 mm)
One Layer 4”x4”x3/8” (102x102x9.5 mm)
11 ga. (3.04 mm) HRPO Steel
HUD-2-RS3680
6”
(152 mm)8.63”
(219 mm)3’0’’
(914 mm)
7’8’’
(2337 mm)
Two Layers 4”x4”x3/8” (102x102x9.5 mm)
11 ga. (3.04 mm) HRPO Steel
HUD-3-RS3680
10”
(254 mm)12.63”
(321 mm)
3’0’’
(914 mm)
7’8’’
(2337 mm)
Two Layers 4”x4”x3/8” (102x102x9.5 mm)
11 ga. (3.04 mm) HRPO Steel
HUD-M-RS3680
3.25”
(82.6 mm)5.88”
(149 mm)3’0’’
(914 mm)
7’8’’
(2337 mm)
One Layer 4”x4”x3/8” (102x102x9.5 mm)
11 ga. (3.04 mm) HRPO Steel
Products are Category A for use in Positive Pressure applications.
Vault Door Hardware is to be installed as per Hamilton Security specifications.
Notes:
Refer to QAI evaluation report F477-1 and the applicable test reports for test assembly configurations used for fire endurance testing.Refer to the QAI FD002 – Fire Door Guidelines for general guidelines of fire door assemblies
Final acceptance of the product in the intended application is to be determined by the authority having jurisdiction (AHJ).
Product is to be installed in accordance with the manufacturer’s published installation instructions by qualified installing personnel.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.