CAN/ULC-S701
Standard for Thermal Insulation, Polystyrene, Boards and Pipe Covering.
CAN/ULC-S102.2
Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies. -
Structural Insulated Panel (SIP) Products,
-
Each panel is marked with a permanent label containing the following information:
a) Manufacturers name or recognized trademark
b) Product name
c) Date of manufacture
d) QAI file number: B1114
e) CAN/ULC-102.2 Flame Spread Index and Smoke Developed Index
f) CAN/ULC S701 Type 1
g) QAI logo shown here: -
* {margin:0; padding:0; text-indent:0; }
.s1 { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: bold; text-decoration: underline; font-size: 14pt; }
.s2 { color: #0E233D; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 11pt; }
.s3 { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 11pt; }
.s4 { color: #00F; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: underline; font-size: 11pt; }
.s5 { color: #0E233D; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 11pt; }
.h1 { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: bold; text-decoration: none; font-size: 11pt; }
.s6 { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 11pt; }
.s7 { color: #FFF; font-family:Arial, sans-serif; font-style: normal; font-weight: bold; text-decoration: none; font-size: 10pt; }
.s8 { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 10pt; }
.s9 { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 6.5pt; vertical-align: 3pt; }
p { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 9.5pt; margin:0pt; }
.a { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: underline; font-size: 9.5pt; }
.s10 { color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 9.5pt; }
li {display: block; }
#l1 {padding-left: 0pt;counter-reset: c1 1; }
#l1> li:before {counter-increment: c1; content: counter(c1, lower-latin)”) “; color: black; font-family:Arial, sans-serif; font-style: normal; font-weight: normal; text-decoration: none; font-size: 11pt; }
#l1> li:first-child:before {counter-increment: c1 0; }The following outlines In-Green Systems Corporation Structural Insulated Panel (SIP) ratings.
In-Green Systems SIP Expanded Polystyrene foam core performance per CAN/ULC-S701.
PROPERTY
Expanded Polystyrene Insulation
Type 1
Thermal Resistance
Minimum at 25 mm Thickness (m2*oC/W)
0.65
Water Vapour Permeance Maximum at 25 mm Thickness (Ng/Pa*s*m2)
300
Dimensional Stability Maximum Linear Change (%)
1.5
Flexural Strength Minimum (kPa)
170
Water Absorption By Volume Maximum (%)
6.0
Compressive Strength Minimum at 10% Deformation (kPa)
70
Limiting Oxygen Index Minimum (%)
24
In-Green Systems SIP Expanded Polystyrene foam core performance per CAN/ULC S102.2.
EXPANDED POLYSTYRENE (EPS) INSULATION
DENSITY
MAXIMUM THICKNESS
FLAME SPREAD INDEX (FSI)
SMOKE DEVELOPED INDEX (SDI)
Type 1
Maximum 17.5
kg/m3
100 mm Maximum
≤ 290
≥ 500
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.