International Fireproof Technology Inc (IFTI)
Building Products Listing Program
- International Fireproof Technology Inc (IFTI)
- Applied Fireproofing
- Irvine, CA
- B1117-3
- B1117-3, Edition 1R2
- April 11, 2019
- March 3, 2021
- N/A
-
ASTM E84 “Standard Test Method for Surface Burning Characteristics of
Building Materials”.UL 723 “Standard for Test for Surface Burning Characteristics of Building
Materials:ANSI/NFPA No 255 “Standard Method of Test of Surface Burning
Characteristics of Building Materials“CAN/ULC-S124 “Standard Method of Test for the Evaluation of Thermal
Barriers for Foamed Plastic”NFPA 285 “Standard Fire Test Method for Evaluation of Fire Propagation
characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing
Combustible Components”.NFPA 286 “Standard Methods of Fire Tests for Evaluating Contribution of Wall
and Ceiling Interior Finish to Room Fire Growth”. -
DC4000-2K Fire Protective Coating.
-
DC4000-2K Fire Protective Coating is a two-component water based nonintumescent
coating.Product is marked with labels or stamp supplied by IFTI to each container. The
markings include:
Manufacturer’s name, trademark, or other recognized symbol of
identification
Product model designation
QAI File Number B1117
Date of manufacture or date code on the label or stamp
Flame Spread Index / Smoke Developed Index Rating
QAI logo shown here: -
The following outlines DC4000-2K coating ratings determined in
accordance with ASTM E84, UL 723, ANSI/NFPA 255 and UBC NO. 8-1SUBSTRATE FLAME SPREAD INDEX (FSI) SMOKE DEVELOPED INDEX (SDI) APPLICATION (WET MILS) NCFI Polyurethane HFO Polyurethane foam ≤ 4” thick and ≤ 2 lbs/ft3 ≤ 25 ≤ 450 60 Note: UL 723 and NFPA No 255 are equivalent and have the same ratings.
The following outlines DC4000-2k water based non-intumescent coating ratings determined in accordance with CAN/ULC S124.
SUBSTRATE RATING APPLICATION (WET MILS) Spray Applied Polyurethane Foam complying with CAN/ULC S705.1 Classification A & B 80 The following outlines DC4000-2k water based non-intumescent coating ratings determined in accordance with NFPA 285
Standard QAI Design # Model Model
RatingNFPA 285 B1117-3-1 DC4000-2K @ min 60 mils Complies NFPA 285 DETAILS OF CONSTRUCTION QAI DESIGN NO B1117-3-1
Component Description Steel studs 3-5/8 in. (92 mm) deep 20 ga galvanized steel spaced 24 in. (609 mm) on center, secured to the track with self-drilling screws. Interior Gypsum Board Type X gypsum board, 5/8 in. (15.9 mm) thick, listed by an
approved agency as complying with ASTM C1396. 4 ft.
(1219 mm) wide, attached to the interior face of steel studs
with 1-5/8 in. (41 mm) long self-tapping screws spaced 8 in.
(203 mm) OC around the perimeter and 12 in. (304 mm) OC
in the field. Joints were oriented vertically and covered with
paper tape and joint compound.Stud Cavity Insulation Accella EcoBay CC 2.0 pcf spray foam insulation installed at
a thickness of nominal 3 in (76 mm) within the stud cavities,
leaving a nominal 5/8 in (15.9 mm) air gap between the
surface of the insulation and interior gypsum board.Exterior Gypsum Board Exterior gypsum board, 5/8 in. (15.9 mm) thick complying
with ASTM C1777 attached to the exterior face of steel studs
with 1-5/8 in. (41 mm) long self-tapping screws spaced 8 in.
(203 mm) OC around the perimeter and 12 in. (304 mm) OC
in the field. Joints not treated.Horizontal Z Girts 20 ga.non-perforated steel z girts with a depth of 3 in
(76mm) and 1 ½ in (38mm) flanges were installed
horizontally over the exterior sheathing, spaced at 4 feet
(1219 mm) OC.Exterior Insulation Accella EcoBay CC 2.0 pcf insulation sprayed at a thickness
of nominal 2 in (51 mm) directly onto the exterior sheathing,
and between the horizontal z girts. A nominal 1 in (25.4 mm)
air gap between the surface of the insulation and outer
flange of the z girts.Spray Coating DC 4000 spray coating was applied at a nominal 60 mil wet
thickness directly onto the exterior Accella EcoBay CC
insulation. Coating sprayed applied onto the entire
assembly; Note additional coats may need to be applied to
obtain final desired 60 mil wet thickness.Steel Corrugated Panels 0.042 inch (1.1 mm) thick, 1-1/2 in (38 mm) deep steel
corrugated panels 3 feet (914mm) wide fastened to the
horizontal z girtsThe following outlines DC4000-2k water based non-intumescent coating ratings determined in accordance with NFPA 286
Standard Model Rating NFPA 286 DC 4000-2K @ min 60 WFT over 5.5” for vertical surfaces & 9.5” for horizontal Surfaces Seal Tite CC+ closed Cell Spray Applied Polyurethane Foam
(≤ 2.2 lbs/ft3)Complies with Acceptance Criteria in Annex C of NFPA 286-15, 2009 IBC section 803.1.2
2009 IRC section 316.6 and 2015 NFPA 101 section 10.2.3.7.2Uses:
DC4000-2K Fire Protective Coating is a two component, weather resistant,
water based non-intumescent coating, for use, on spray applied foam insulation.
When DC4000-2K is applied to spray foam insulation, the coated foam plastic
assembly may be left exposed as the interior finish in lieu of a prescriptive
thermal barrier.
For application the manufacturers installations instructions must be followed,
foam MUST be cured and cooled to ambient conditions, all surface preparation
should be carried out in accordance with good painting practices and the
DC4000-2K must be thoroughly mixed before being spray applied.
The mil thickness should to be checked during installation to ensure minimum
noted thickness are maintained.See Manufactures Approved Design and Installation Documents.
Final acceptance of the product in the intended application is to be determined by the authority having jurisdiction.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.