LOGIX BRANDS, LTD.
Building Products Listing Program
- LOGIX BRANDS, LTD.
- Thermal Insulation
- 9242 Pinetree Place, Whistler, BC, Canada V0N 1B9
- B1031-2
- B1031-2
- May 30, 2014
- January 23, 2024
- N/A
-
CAN/ULC S701.1
Thermal Insulation, Polystyrene, Boards and Pipe Covering.
CAN/ULC S102.2
Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies.
ASTM C578
Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation.
ASTM E84
Standard Test Method for Surface Burning Characteristics of Building Materials.
-
Halo™ Expanded Polystyrene (EPS) Thermal Insulation
Heat Sheet™ Expanded Polystyrene Subfloor Insulation Products
Halo Type 1 (Type VIII), Type 2 (Type II), Type 3 (Type IX) Expanded Polystyrene Film Faced rigid thermal insulation products. Come in the following product options:
HALO SubTerra Type 1 / Type VIII EPS Insulation
HALO SubTerra Type 2 / Type II EPS Insulation
HALO SubTerra Type 3 / Type IX EPS Insulation
HALO ExTerra Type 1 / Type VIII EPS Insulation
HALO ExTerra Type 3 / Type IX EPS Insulation
HALO InTerra Type 1 / Type VIII EPS Insulation
Heat Sheet Type 2 (Type II) Radiant floor thermal insulation.
Heat Sheet Type 3 (Type IX) Radiant floor thermal insulation. -
Products are marked in a permanent manner with the following:
a)Company Name: Logix Brands
b)ASTM C578 / CAN/ULC S701.1 Type as appropriate.
c)CAN/ULC S102.2 / ASTM E84 Flame Spread Smoke Developed Index (FSI ≤ 25 / SDI ≤ 450).
d)RSI values (required for Canadian products per CAN/ULC S701.1).
e)Traceability code including date of manufacture.
f)QAI Mark as shown below: - Product is marked with labels supplied by LOGIX Insulated Concrete Forms, Ltd. The label includes the manufacturer’s name, trademark, or other recognized symbol of identification, the product model designation, month and year of manufacture or equivalent, QAI logo with the ‘US’ and “C” identifier, and CAN/ULC S701 Type, ASTM C578 Type, CAN/ULC S102.2, and ASTM E84 FSI and SDI Rating. Labels are applied to palletized finished products to ensure visibility on the jobsite.
-
The following outlines Halo™ and Heat Sheet Expanded Polystyrene (EPS) Thermal Insulation Performance determined in accordance with the noted standards.
Halo™ Expanded Polystyrene Thermal Insulation Properties per CAN/ULC S701.1:PROPERTY
TYPE 1
TYPE 2
TYPE 3
Thermal Resistance Minimum at 25 mm
(1 inch) Thickness
See Table Below
See Table Below
See Table Below
Water Vapour Permeance Maximum at 25 mm Thickness (Ng/Pa*s*m2)1
300
200
130
Dimensional Stability Maximum Linear Change (%)
1.5
1.5
1.5
Flexural Strength Minimum (kPa)
170
240
300
Water Absorption by Volume Maximum (%)
6.0
4.0
2.0
Compressive Strength
Minimum at 10% Deformation (kPa)
70
110
140
Limiting Oxygen Index Minimum (%)
24
24
24
1: Value is for EPS thermal insulation only and does not include facer.
Heat Sheet Expanded Polystyrene Thermal Insulation Properties per CAN/ULC S701.1:
PROPERTY
TYPE 2
TYPE 3
Thermal Resistance Minimum at 25 mm
(1 inch) Thickness
0.70
0.74
Water Vapour Permeance Maximum at 25 mm Thickness (Ng/Pa*s*m2)1
200
130
Dimensional Stability Maximum Linear Change (%)
1.5
1.5
Flexural Strength Minimum (kPa)
240
300
Water Absorption By Volume Maximum (%)
4.0
2.0
Compressive Strength
Minimum at 10% Deformation (kPa)
110
140
Limiting Oxygen Index Minimum (%)
24
24
Halo™ Expanded Polystyrene Thermal Insulation Properties per ASTM C578:
PROPERTY
TYPE VIII
TYPE II
TYPE IX
Compressive Strength
Minimum @ 10% Deformation (psi)
13.0
15.0
25.0
Thermal Resistance Minimum @ 1 inch Thick (F*ft2*h/Btu)
See Table Below
See Table Below
See Table Below
Water Vapor Permeance
@ 1 inch Thickness Maximum (Perms)1
3.5
3.5
2.5
Water Absorption
By Volume Maximum (%)
3.0
4.0
2.0
Dimensional Stability
Linear Change Maximum (%)
2.0
2.0
2.0
Oxygen Index
Minimum (%)
24.0
24.0
24.0
Density Minimum (lbs/ft3)
1.15
1.35
1.80
1: Value is for EPS thermal insulation only and does not include facer.
Heat Sheet Expanded Polystyrene Thermal Insulation Properties per ASTM C578:
PROPERTY
TYPE II
TYPE IX
Compressive Strength
Minimum @ 10% Deformation (psi)
15.0
25.0
Water Vapor Permeance
@ 1 inch Thickness Maximum (Perms)
3.5
2.5
Water Absorption
By Volume Maximum (%)
4.0
2.0
Dimensional Stability
Linear Change Maximum (%)
2.0
2.0
Oxygen Index
Minimum (%)
24.0
24.0
Density Minimum (lbs/ft3)
1.35
1.80
Thermal Resistance Properties for Halo in accordance with ASTM C518
Halo Type
Minimum
Density kg/m3 (lb/ft3)
Thermal Resistance @ 1 inch (25 mm) at 75oF
(23oC) Mean Temperature K*m2/W
(F*ft2*h/Btu)
Thermal Resistance @ 1-1/6 inch (27mm) Thickness at 75oF
(23oC) Mean Temperature K*m2/W (F*ft2*h/Btu)
Halo Interra / Exterra Type 1 (Type I)
15
(0.95)
0.83
(4.7)
0.88
(5.0)
Halo Exterra Type 1 (Type VIII)
18
(1.15)
0.83
(4.7)
0.88
(5.0)
Halo Subterra / Subterra Plus Type 2 (Type II)
22
(1.35)
0.83
(4.7)
0.88
(5.0)
Halo Subterra / Subterra Plus Type 2 (Type II)
23
(1.45)
0.83
(4.7)
0.88
(5.0)
Halo Subterra / Subterra Plus Type 3 (Type IX)
29
(1.80)
0.83
(4.7)
0.88
(5.0)
Halo™ and Heat Sheet Expanded Polystyrene Thermal Insulation Surface Burning Characteristics per CAN/ULC S102.2
LOGIX HALO and HEAT SHEET
INSULATION
DENSITY
MAXIMUM THICKNESS
FLAME SPREAD INDEX (FSI)
SMOKE DEVELOPED INDEX (SDI)
Type 1, Type 2, Type 3
Maximum 32 kg/m3
100 mm Maximum
≤ 210
≥ 500
Halo™ and Heat Sheet Expanded Polystyrene Thermal Insulation Surface Burning Characteristics per CAN/ULC S102.2
LOGIX
COMPONENT
DENSITY
MAXIMUM THICKNESS
FLAME SPREAD INDEX (FSI)
SMOKE DEVELOPED INDEX (SDI)
Expanded Polystyrene
(EPS Panel)
35.2 kg/m3
100 mm Maximum
≤ 250
≥ 500
Halo™ and Heat Sheet Expanded Polystyrene Thermal Insulation Surface Burning Characteristics per ASTM E842
LOGIX HALO and HEAT SHEET
INSULATION
DENSITY
MAXIMUM THICKNESS
FLAME SPREAD INDEX (FSI)
SMOKE DEVELOPED INDEX (SDI)
Type VIII, Type II, Type IX
Maximum 2.20 lbs/ft3
4.0 Inches Maximum
≤ 25
≤ 450
2: Ceiling measurement only. This measurement is conducted through determination of flame spread index and smoke developed index with the removal of any contribution of molten materials ignited on the floor of the tunnel assembly
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.