Norbec Architectural Inc.
Building Products Listing Program
- Norbec Architectural Inc.
- Insulated Metal Wall Panels
- Boucherville, Quebec, Canada
- B1096-2
- B1096-2
- October 31, 2017
- September 30, 2019
- N/A
-
CAN/ULC S102 “Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.”
CAN/ULC S126 “Standard Method of Test for Fire Spread Under Roof Deck Assemlbies.”
CAN/ULC S101 “Standard Methods of Fire Endurance Tests of Building Construction and Materials”.
ASTM E119 “Standard Test Methods for Fire Tests of Building Construction and Materials.” -
Norbec NOROC-L Mineral Wool Steel Skinned Insulated Metal Panels
-
The following outlines Norbec NOROC Mineral Wool Insulated Metal Panels performance determined in accordance with the noted standards. The ratings outlined in the tables below are achieved in assemblies that are defined in the QAI Design Listings.
NOROC-L Mineral Wool Insulated Metal Panels Surface Burning Characteristics per CAN/ULC S102
Model (s) Flame Spread Index Max. Smoke Developed Index Max. Thickness Maximum NOROC-L Core 0 0 100-203 mm
4-8 InchesNOROC-L Panel < 25 < 150 100-203 mm
4-8 InchesNOROC-L Mineral Wool Insulated Metal Panels results of evaluated to CAN/ULC S126
Model (s) Results Thickness Max. (mm) NOROC-L Complies 100-203 mm
4 – 8 inchesNOROC-L Mineral Wool Insulated Metal Panels per CAN/ULC-S101 & ASTM E119 – Non-Loadbearing Walls and Partitions
QAI Design # Model: Fire Resistance Rating: B1096-2a 100 mm (4 Inch) NOROC-L Panels 45 min B1096-2a 126 mm (5 Inch) NOROC-L Panels 1 hour B1096-2a 152 mm (6 Inch) NOROC-L Panels 2 hours B1096-2a 203 mm (8 inch) NOROC-L Panels 3 hours B1096-2b 2 Layer 100 mm (4 Inch) NOROC-L Panels, Staggered Joints 3 hours
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.