Norbec Architectural Inc.
Building Products Listing Program
- Norbec Architectural Inc.
- Insulated Metal Wall Panels
- Boucherville, Quebec, Canada
- B1096-2
- B1096-1 Edition 9
- October 31, 2017
- March 7, 2025
- N/A
-
CAN/ULC S102-18
“Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.”
CAN/ULC S126-14
“Standard Method of Test for Fire Spread Under Roof Deck Assemblies.”
CAN/ULC S101-14
“Standard Methods of Fire Endurance Tests of Building Construction and Materials”.
ASTM E119-24
“Standard Test Methods for Fire Tests of Building Construction and Materials.”
-
Norbec NOROC-L Mineral Wool Core Insulated Metal Panels
-
The following outlines Norbec NOROC Insulated Metal Panels performance determined in accordance with the noted standards. The ratings outlined in the tables below are achieved in assemblies that are defined in the QAI Design Listings.
NOROC-L Insulated Metal Panels Surface Burning Characteristics per CAN/ULC S102:
Model
Flame Spread Index Max.
Smoke Developed Index Max.
Thickness Range
NOROC-L Core
0
0
102 – 203 mm
(4 – 8 Inches)
NOROC-L Panel
< 25
< 150
102 – 203 mm
(4 – 8 Inches)
NOROC-L Insulated Metal Panels results of evaluated to CAN/ULC S126:
Model
Panel Thickness Range
Results
NOROC-L
102 – 203 mm
(4 – 8 Inches)
Complies with CAN/ULC S126.
NOROC-L Insulated Metal Panels per CAN/ULC-S101 & ASTM E119 – Non-Loadbearing Walls and Partitions:
QAI Design #
Model
Minimum Panel Thickness
Fire Resistance Rating
B1096-2a
NOROC-L
102 mm (4-inch)
45 minutes
NOROC-L
127 mm (5-inch)
1 hour
NOROC-L
152 mm (6-inch)
2 hours
NOROC-L
203 mm (8-inch)
3 hours
NOROC-L
Two 102 mm (4-inch) Layers, Staggered Joints
3 hours
NOROC-L Insulated Metal Panels per CAN/ULC-S101 & ASTM E119 – Non-Loadbearing Floor/Ceiling Assembly:
QAI Design #
Model
Minimum Panel Thickness
Fire Resistance Rating
NOROC-L
102 mm (6-inch)
90 minutes
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.