Owens Corning Canada LP
Building Products Listing Program
- Owens Corning Canada LP
- Thermal Insulation
- Scarborough, Ontario
- B1079
- B1079-1
- January 30, 2017
- October 22, 2024
- N/A
-
CAN/ULC-S124-06
Standard Method of Test for the Evaluation of Protective Coverings for Foamed Plastic -
Thermafiber Mineral Wool Thermal Insulation Products:
•VersaBoard™ 60 unfaced and faced.
•Rainbarrier® ci High Compressive (80)
•Fire & Sound Guard® Plus -
Listed products are identified with a label bearing the following information:
a)Owens Corning trademark
b)Production line identification code and country of manufacture
c)Product name (and R-Value if applicable)
d)Date of production -
The following outlines Thermafiber VersaBoard™ 60, Rainbarrier® ci High Compressive (80), and Fire & Sound Guard® Plus mineral wool thermal insulation performance determined in accordance with the noted standards. The ratings outlined in the tables below are achieved in assemblies that are defined in the QAI Design Listings.
QAI DESIGN #
MINIMUM BOARD THICKNESS
CLASSIFICATION
2”
B
3”
A
Thermafiber Fire & Sound Guard® Plus mineral wool thermal insulations are protective coverings for foamed plastic per CAN/ULC-S124 for use over foam plastic insulation of a maximum R value of of 7.5/inch.1
QAI DESIGN #
MINIMUM
BATT THICKNESS
MINIMUM
BATT
R-VALUE
CLASSIFICATION
3.5”
R14
B
5.5”
R20
A
1. Additional variations of Thermafiber Fire & Sound Guard® Plus with equal or greater R-Value and thickness will achieve the same classification as listed above.
Note
•Final acceptance of the product in the intended application is to be determined by the authority having jurisdiction (AHJ).
•Product is to be installed in accordance with the QAI Design Listing and manufacturer’s published installation instructions by qualified installing personnel.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.