Pocket House Inc.
Factory Built Structures Listing Program
- Pocket House Inc.
- Business Commercial Industrial Structures, Group D
- Lac Ste, Anne County, Alberta
- REC624-2
- REC624-2
- August 22, 2016
- March 19, 2024
- N/A
-
•National Building Code
•National Building Code – Alberta Edition
•BC Building Code
•BC Plumbing Code
•National Plumbing Code
•Canadian Electrical Code Part 1 “Safety Standard for Electrical Installations”
•CSA B149.1 “Propane and Natural Gas Installation Code”
•CSA A277 Procedure for Certification of Prefabricated Buildings, Modules, and Panels.Note: Unless otherwise specified, the standards/codes noted above are the most current versions in effect.
-
Factory Constructed Business Commercial Structures
-
Products are marked in a permanent manner where it is readily visible after installation with the following:
1.The specification nameplate (item 1068, white with black, 8-1/2” x 14”) is located in close proximity to the electrical panel and includes:
•Manufacturer’s Name and Address
•Date of Manufacture
•Model Serial Number or Product Code
•Foundation Type (Perimeter Foundation Wall or Piers)
•Floor live Load
•Specified Snow Load (1/50)
•Seismic Response Sa(0.2)
•Hourly Wind Pressure (1/50)
•Envelope Effective Thermal Resistance
•Windows/Doors/Skylights Thermal Characteristics
•Outside Design Temperature (Heal Loss or Heat Gain)
•Factory Installed Appliances
•Site Installed Components, Assemblies, and Systems
•Electrical Systems Voltage, Frequency, and Amperage2.The QAI label (item 1096 – Permanent Business Commercial Industrial Building CSA A277 Compliance label) is normally located in close proximity to the electrical panel.
•Certification label with serial number
•QAI Certification Logo with the ‘c’ identifier,
•QAI Logo shown here: -
Structures are used for single Major Occupancy (classified as Group D – Business and Personal Services occupancies), constructed in single or multiple modules, of up to 3-storey or less in building height, with a building area not exceeding 600 m2. Units classified under this occupancy are not intended for general public access.
Structures under this listing typically include units used as business offices or for personal services. For a full list of structures covered under this occupancy please refer to Division B, Notes to Part 3, A-3.1.2.1.(1) Major Occupancy Classification in the Building Code. This listing does not include structures with multiple Major Occupancies nor does it include the certification of elevators.
Structural:
Conventional Wood Frame Construction within the limitations of Part 9 applicable Building Code. Units may be constructed with Engineered Floor and Roof Systems.Electrical Ratings:
120/208V, 3PH, 60Hz, 600A Max. or 120/240V, 1PH, 60Hz, 600A Max.Heating/Ventilation:
The structures may be equipped with electrical baseboard heaters, energy recovery ventilators or high-velocity fan coil system operating with a Gas-fired, on-demand, tankless boiler.Plumbing:
Conventional drainage and venting systems up to a maximum of 240 hydraulic fixture units.Gas Systems:
The certification only covers factory installed portions of the gas system. Final installation and commissioning of the gas system must be completed on site by qualified technicians as per the requirements of the Authority Having Jurisdiction.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.