Triple M Housing Ltd.
Factory Built Structures Listing Program
- Triple M Housing Ltd.
- Permanent Engineered Structures
- Lethbridge, AB
- REC579-13
- REC579-13
- January 10, 2018
- January 10, 2018
- N/A
-
CSA A277 “Procedure for Certification of Prefabricated Buildings, Modules, and Panels”
Alberta Building Code 2014
National Building Code
National Plumbing Code
CSA C22.1-15 “Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations”Note: Unless otherwise specified, the standards/Code noted are the most current versions in effect.
-
Factory Built Permanent Engineered Structures
-
All markings must be permanent and visible after installation.
1. The QAI label with ‘C’ identifier (item 1097 – Permanent Engineered Structures CSA A277 Compliance Label) is normally located in close proximity to the electrical panel and displays the QAI logo shown here:
2. The specification nameplate (item 1068, 8-1/2” x 14” in size) is located in close proximity to the electrical panel and includes:
• Manufacturer’s Name and Address
• Date of Manufacture
• Model Serial Number or Product Code
• Foundation Type (Perimeter Foundation Wall or Piers)
• Floor live Load
• Specified Snow Load (1/50)
• Seismic Response Sa(0.2)
• Hourly Wind Pressure (1/50)
• Envelope Effective Thermal Resistance
• Windows/Doors/Skylights Thermal Characteristics
• Outside Design Temperature (Heal Loss or Heat Gain)
• Factory Installed Appliances
• Site Installed Components, Assemblies, and Systems
• Electrical Systems Voltage, Frequency, and Amperage3. Other Markings as required by the relevant codes.
The QAI label and specification nameplate are available from QAI and must be applied at the factory.
-
The scope of buildings covered in this listing include:
Buildings:
Permanent Engineered Structures under Part 3, 4, 5 and 6 of the National Building Code and Alberta Building Code. Structures are used for single Major Occupancy classified as Group B, Division 2 – Care occupancies, constructed in single or multiple modules in single storey configurations.
Structures under this listing typically include units used as Daycares. These listing do not include structures with multiple Major Occupancies.
For a full list of structures covered under this occupancy please refer to Division B, Section A-3.1.2.1.(1) of the National Building Code.
Structural:
Conventional Wood Frame Construction
Electrical Ratings:
120/240V, 60Hz, 200A Max.
Heating/Ventilation:
Central forced air furnaces. Units may be electric. Systems may be equipped with air conditioning
Plumbing:
Conventional drainage and vent systems to a maximum of 240 hydraulic fixture units.
Fire alarm and sprinkler system is installed on site by Simplex. This is not covered under this certification.
Gas Systems:
None
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.