Westlake Royal Roofing LLC
Building Products Listing Program
- Westlake Royal Roofing LLC
- Clay Roof Tiles
- 7575 Irvine Center Drive, Suite 100
Irvine, CA 92618 - B1044-1
- B1044-1
- March 29, 2012
- April 30, 2022
- N/A
-
ASTM C 1167 – Standard Specification for Clay Roof Tiles.
ASTM E 108 – Standard Specification for Fire Tests of Roof Coverings.
CAN/ULC S107 – Standard Methods of Fire Tests of Roof Coverings.
FM 4473 – Test Standard for Impact Resistance Testing of Rigid Roofing Materials by Impacting with Freezer Ice Balls. -
USTile® Clay Roofing Tiles
-
Products are palletized and marked with a label that includes the following information.
a) USTile® Name or Logo
b) Product Profile
c) Plant Location and Address
d) SAP Number
e) Color Description
f) Quantity of tiles per pallet
g) Production Date
h) QAI file Number: B1044-1
i) The wording “Grade 1“(when applicable)
j) FM 4473 Class 3 (when applicable)
k) ASTM E108/CAN ULC S107 Class A
l) QAI logo shown here: -
Claylite Tile1 Claymax Tile1 Length, inches 18 (-0.125 / +0.25) 18 (-0.125 / +0.25) Width, inches 13 ± 0.125 12.625 (-0.125 / +0.25) Height, inches 2.25 ± 0.125 1 ± 0.125 Mass, grams 3002 2993 One Piece “S”1 Romano Pan1 Length, inches 18 (-0.125 / +0.25) 18 (-0.125 / +0.25) Width, inches 13 ± 0.25 11 ± 0.25 Height, inches 2.375 ± 0.125 1.73 ± 0.125 Mass, grams 3855 2948 2-Piece Mission Tile1 2-Piece Mission Monarch 2 Length, inches 18 (-0.125 / +0.25) 18 (-0.125 / +0.25) Nose Width, inches 8.5 ± 0.25 6.75 ± 0.25 Head Width, inches 7 (-0.25 / +0.125) 5.25 (-0.25 / +0.125) Nose Height, inches 2.50 ± 0.25 2.87 ± 0.25 Head Height, inches 1.750 ± 0.25 2.13 ± 0.25 Mass, grams 2721 2041 Notes: 1. Grade 1 Tiles are designed to provide resistance to severe frost action. This grading is necessary for installations across Canada and sections of severe weathering across the United States in accordance with Fig A1.1, ASTM C1167.
2. Does not meet ASTM C1167 Grade 1.Class A Roofing Assembly: Unlimited Slope
-In accordance with ASTM E108 and CAN/ULC S107Sheathing Underlayment Roof Covering Minimum 15/32-inch AC Exterior Plywood Minimum one layer Type II (No. 30) asphalt-saturated felt complying with ASTM D226/CSA A123.3, Type 2. Claylite Tile Claymax Tile
One Piece “S”
Romano Pan
2-Piece Mission
2-Piece Mission MonarchMinimum one layer of Sol-R-Skin® BLUE underlayment mechanically fastened with a head overlap of 6-inches Class 3 Impact Resistant Assembly
-In accordance with FM 4473Sheathing Underlayment Roof Covering Minimum 15/32-inch AC Exterior Plywood Unrestricted One-Piece “S”
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.