Wildhawk Investments, LLC dba Brava Roof Tile
Building Products Listing Program
- Wildhawk Investments, LLC dba Brava Roof Tile
- Plastic Roof Tiles
- 915 E. Tyler Street, Washington, IA
- B1138
- B1138-1
- August 30, 2022
- October 25, 2023
- N/A
-
ASTM E108 Standard Test Methods for Fire Tests of Roof Coverings.
UL 790 Standard Test Methods for Fire Tests of Roof Coverings.
UL 2218 Impact Resistance of Prepared Roof Covering Materials. -
Brava Roof Tile roof coverings are polymeric products available in the following models:
• Brava Slate
• Brava Cedar Shake
• Brava Spanish Barrel Tile
• Brava Flat Tile -
Ratings:
The following outlines roof-fire classified assemblies determined in accordance with ASTM E108 / UL 790 and UL 2218:
Assembly 1:
Class A Roofing Applications: Unlimited Slope
SHEATHING
UNDERLAYMENT
APPROVED ROOF COVERING(s)
Maximum Exposure (inches)
Minimum 15/32’’ (12mm) Exposure 1
Plywood
1 layer of ASTM D226 Type II asphalt felt, with joints overlapped minimum 6 inches (152 mm).
Brava Slate Class A
Brava Cedar Shake Class A
Brava Spanish Barrel Tile Class A
10
10
13.5
Minimum 15/32’’ (12mm) Exposure 1
Plywood
1 layer of 4LMPX Low-E Therma Sheet underlayment with joints overlapped minimum 4 inches (102 mm).
Brava Slate Brava One
Brava Cedar Shake Brava One
10
10
Minimum 15/32’’ (12mm) Exposure 1
Plywood
1 layer of Eco Chief Solarhide underlayment with joints overlapped minimum 4 inches (102 mm).
Brava Slate Brava One
Brava Cedar Shake Brava One
10
10
Assembly 2:
Class C Roofing Applications: Unlimited Slope
SHEATHING
UNDERLAYMENT1
APPROVED ROOF COVERING(s)2
Maximum Exposure (inches)
Minimum 15/32’’ (12mm) Exposure 1
Plywood
1 layer of ASTM D226 Type II asphalt felt, with joints overlapped minimum 6 inches (152 mm).
Brava Slate Brava One
Brava Cedar Shake Brava One
Brava Spanish Barrel Tile Brava One
10
10
13.5
Minimum 15/32’’ (12mm) Exposure 1
Plywood
1 layer of Intertape Polymer Group® Palisade® synthetic underlayment, overlapped minimum 4 inches (102 mm).
Brava Flat Tile Brava One
14
Assembly 3:
Impact Resistant (Class 4) Applications: Unlimited Slope
SHEATHING
UNDERLAYMENT1
APPROVED ROOF COVERING(s) 2
Maximum Exposure (inches)
Minimum 15/32’’ (12 mm) Exposure 1
Plywood
Unrestricted
Brava Slate Class A
Brava Cedar Shake Class A
Brava Spanish Barrel Tile Class A
Brava Slate Brava One
Brava Cedar Shake Brava One
Brava Spanish Barrel Tile Brava One
Brava Flat Tile Brava One
10
10
13.5
10
10
13.5
14
Note 1: Underlayment components are to be installed in accordance with the manufacturer’s published installation instructions.
Note 2: These products are listed and labeled under QAI’s certification program.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.