Woodland Crafted Homes Ltd.
Recreational Vehicles Listing Program
- Woodland Crafted Homes Ltd.
- CSA Z240MH Series Manufactured Homes
- Kelowna, BC
- REC775-1
- REC775-1
- March 10, 2022
- March 10, 2022
- N/A
-
CSA A277-16 “Procedure for certification of prefabricated buildings, modules, and panels”,
CSA Z240MH Series “Manufactured Homes”
With reference to:
National Building Code of Canada
National Plumbing Code of Canada, and
CSA C22.1 Canadian Electrical Code, Part 1Note: Unless otherwise specified, the Standards/Codes noted above are the most current versions in effect.
-
Manufactured Homes
-
All markings must be permanent and visible after installation.
The QAI label (item 1065, white lettering on green background, 3-1/2” in diameter) for Multiple Section Homes is normally located in close proximity to the electrical panel or next to the main entrance to the unit.
The CSA Z240MH Specification Nameplate (item 1072, black lettering on white background, 8-1/2” x 14”) is located on the inside of a kitchen cabinet door or the master bedroom closet and includes:
• Manufacturer’s Name and Address
• Date of Manufacture,
• Model Serial Number or Product Code,
• Foundation Type (perimeter foundation wall or piers),
• Floor Live Load,
• Specified Snow Load (1/50),
• Seismic Response Sa(0.2),
• Hourly Wind Pressure (1/50),• Building Envelope Effective Thermal Resistance,
• Windows/Doors/Skylights Thermal Characteristics,
• Outside Design Temperature (Heat Loss/Heat Gain),
• Factory Installed Appliances,
• Site Installed Components, Assemblies, and Systems, and
• Electrical Systems Voltage, Frequency, and Amperage. -
The Scope of Homes covered in this listing include:
Homes:
Single family manufactured housing comprised of multiple modules in single storey configuration.Structural:
Conventional Wood Frame Construction with Roof and Floor Truss systems designed in Part 4 by P.Eng. Wood framing components outside of Part 9 designed by P.Eng. in Part 4Electrical:
120/240V, 60Hz, 1PH, 200 Amps max.Heating/Ventilation:
Units are equipped with forced air furnacesPlumbing:
Conventional drain and vent system to a maximum of 240 hydraulic fixture units.Gas:
None, site installed
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.