Hercutech Incorporated
Building Products Listing Program
- Hercutech Incorporated
- Insulated Concrete Forms
- Peorie, Arizona USA
- B1123-1
- B1123-1 ED 5
- November 25, 2020
- February 23, 2023
- N/A
-
ASTM C578 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation. UL 723 Standard for Test for Surface Burning Characteristics of Building Materials. ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials. NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components. -
HercuWall® Series 8 Panels and Accessories of the following types:
• Type S Panels
• Type SW Panels
• Type A Panels
• HercuWall® Seaming TapeHercuWall® Series 8 are available in an 8’’ and 12’’ concrete stud spacing, and Solid Shear wall option with solid concrete core (Type A panels are not available in Solid Shear wall options).
Additional accessories are available for use with HercuWall® Series 8 panels. Refer to QAI report CERUS-1003 for details.
-
Each panel is marked with a permanent label containing the following information:
a) Manufacturers name or recognized trademark.
b) Product name
c) Traceability Code
d) Reference to QAI file B1123-1 and report CERus-1003
e) ASTM E84 Flame Spread Index and Smoke Developed Index (FSI ≤ 25 / SDI ≤ 450)
f) QAI logo shown here: -
The following outlines HercuWall® Series 8 Panels performance determined in accordance with the noted standards.
HercuWall® Series 8 Panels thermal insulation specifications per ASTM C578:
PROPERTY Expanded
Polystyrene
Insulation
TYPE II TYPE IX Compressive Strength
Minimum @ 10% Deformation (psi)15.0 25.0 Thermal Resistance
Minimum @ 1 inch Thick (F*ft2*h/Btu)4.0 4.2 Flexural Strength Minimum (psi) 35.0 50.0 Water Vapor Permeance
@ 1 inch Thickness Maximum (Perms)3.5 2.5 Water Absorption By Volume Maximum (%) 3.0 2.0 Dimensional Stability Linear Change Maximum (%) 2.0 2.0 Oxygen Index Minimum (%) 24.0 24.0 Density Minimum (lbs/ft3) 1.35 1.80 HercuWall® Series 8 Panels thermal insulation surface burning characteristics determined in accordance with UL 723:
EXPANDED
POLYSTYRENE
(EPS)
INSULATIONDENSITY MAXIMUM
THICKNESSFLAME
SPREAD
INDEX (FSI)SMOKE
DEVELOPED
INDEX (SDI)Type II – Type IX EPS Maximum
2.65
lbs/ft38.5 Inches
Maximum≤ 25 ≤ 450 HercuWall® Series 8 Panels fire-resistance ratings per ASTM E119 –
Loadbearing† Walls and Partitions:QAI Design
#Fire Resistance Rating Sheathing B1123-1a ASTM E119 – HercuWall® Series 8 Panels 1 Hour– Load Bearing1 Fire Resistance-Rated Wall Assembly 1 Layer 5/8 (16 mm) Type X gypsum each face. B1123-1b ASTM E119 – HercuWall® Series 8 CFC Box Beam Panels 1 Hour– Load Bearing1 Fire Resistance-Rated Wall Assembly 1 Layer 5/8 (16 mm) Type X gypsum each face. B1123-1c ASTM E119 – HercuWall® Series 8 Panels 2 Hour– Load Bearing1 Fire Resistance-Rated Wall Assembly 2 Layers 5/8 (16 mm) Type X gypsum each face. B1123-1d ASTM E119 – HercuWall® Series 8 CFC Box Beam Panels 2 Hour– Load Bearing1 Fire Resistance-Rated Wall Assembly 2 Layers 5/8 (16 mm) Type X gypsum each face. 1 Refer to report CERUS-1003 for allowable loading for HercuWall® Series 8 Panels used in Fire-Resistance Rated Assemblies
HercuWall® Series 8 Panels have been evaluated for potential to propagate fire per NFPA 285 and found compliant for the following exterior walls assemblies:
QAI Design
#Assembly Results B1123-1e HercuWall® Type S, SW and A Panels, used in Exterior Walls Cladding per Design Listing B1123-1e Complies with NFPA 285 Requirements Notes:
Products must be installed with the manufacturer’s published installation instructions and in accordance with the building codes recognized by the authority having jurisdiction.
Product is to be installed in accordance with the QAI Design Listing and manufacturer’s published installation instructions by qualified installing personnel.
Final acceptance of the installed product is to be determined by the authority having jurisdiction.
Listed manufacturers are subject to on-going inspections by QAI to ensure that the products outlined above remains as it is listed.
-
QAI maintains ISO/IEC 17065 accreditations via the International Accreditation Service (IAS) for the United States and Canada. Typically, certifications under this accreditation do not require the Seal of a Professional Engineer in order to be accepted by the authority having jurisdiction. Should a Professional Engineer Seal be needed, please select from the highlighted States / Provinces that are available for this specific manufacturer’s file. If a specific State / Province is not available, you may email info@qai.org to request if a sealed document is available for that jurisdiction.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.