USA 888.540.4024      CANADA 877.461.8378
info@qai.org
  • HOME
  • NEWS
  • EVENTS
QAIQAIQAIQAI
  • Company
    • About QAI
    • The QAI Team
    • Locations
    • News
    • Join Our Team
      • Open Positions Canada
      • Open Positions United States
      • Open Positions International
    • Contact
  • Resources
    • Brochures
    • Label Order Online Portal
    • Accreditations
    • Videos
    • Reported Fraudulent Deliverables
  • SERVICES
    • Core Services
      • Product Certification Services
      • Product Testing Services
      • Product Quality Inspection Services
      • Code Evaluation Report Service
      • Geotechnical Engineering Services
    • Industry Focus
      • Electrical Safety
      • Electromagnetic Compatibility (EMC) Testing & Certification Laboratory
      • Machinery Safety
      • Materials Testing
      • Calibration Services
      • Factory Built Structures
      • Certification of RVs and Park Model Trailers
      • Transport Canada
      • Plumbing Certification
      • Testing and Certification of Gas Products
      • Building Products Testing and Certification
      • Fenestration Testing and Certification
      • Fire Doors & Protective Openings
        • Fire Doors Testing and Certification
        • Field Evaluation and Labeling of Fire Doors
    • Solutions
      • Carbon Footprint Product Certification
      • Solar & Photovoltaic Panel Fire Testing
      • Fire and Flammability Testing for Materials
      • Hazardous Location Testing and Certification
      • Special Inspections on Electrical Devices
      • Semiconductor Safety Services – SEMI S2
      • China Compulsory Certification (CCC)
      • China Wireless SRRC Certification
    • Listing Directory
      • Building Products – Directory
      • Electrical Products – Directory
      • Plumbing Products – Directory
      • Code Evaluation Reports – Directory
      • Windows & Doors – Directory
  • LISTING DIRECTORY

Listing Directory

    Home directory Logix Brands, Ltd.
    • Listing Directory
      • Building Products
        • Code Evaluation Report
        • Windows & Doors
      • Consumer Products
      • Electrical Products
      • Factory Built Structures
      • Gas and Solid-Fuel Products
      • Plumbing Products
        • EPA WaterSense Products
      • RV Products
    « Return to Building Products Directory
    Download Listing Doc
    Download Code Report

    Logix Brands, Ltd.

    Building Products Listing Program

    • Logix Brands, Ltd.
    • Insulated Concrete Forms (ICF)
    • Whistler, BC Canada
    • www.logixbrands.com
    • B1031-1
    • B1031-1, Edition 4
    • September 27, 2010
    • March 12, 2024
    • N/A
    • CAN/ULC S717.1

      Standard for Flat Wall Insulating Concrete Form (ICF) Systems.

      ASTM E2634

      Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems.

      ASTM D1761

      Standard Test Methods for Mechanical Fasteners in Wood and Wood-Based Materials.

      CAN/ULC S701.1

      Thermal Insulation, Polystyrene, Boards and Pipe Covering.

      ASTM C578

      Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation.

      CAN/ULC S102.2

      Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies.

      ASTM E84

      Standard Test Method for Surface Burning Characteristics of Building Materials.

      ASTM D2843

      Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics

      UL 1715

      Fire Test of Interior Finish Material 

      ASTM D635

      Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

      ASTM D1929

      Standard Test Method for Determining Ignition Temperature of Plastics.

      ASTM E119

      Standard Test Methods for Fire Tests of Building Construction and Materials.

      CAN/ULC S101

      Standard Methods of Fire Endurance Tests of Building Construction and Materials.

      UL 263

      Standard for Fire Tests of Building Construction and Materials.

    • Insulated Concrete Forms (ICF) are available in the following Models:
      •Logix ICF
      •Element™ ICF

    • Product is marked with labels supplied by Logix Brands Ltd. Products are marked in a permanent manner where it is readily visible after installation with the following:
      a) Manufacturer’s name or trademark
      b) Product model designation
      c) Month and year of manufacture
      d) QAI file Number: B1031-1
      e) CAN/ULC S701.1 Type 2, ASTM C578 Type II,
      f) ASTM E84 FSI and SDI Rating (FSI ≤ 25 / SDI ≤ 450) and
      g) CAN/ULC S102.2 FSI and SDI ratings (FSI ≤ 230 / SDI ≥ 500).
      h) QAI logo shown here:

       

    • Product is marked with labels supplied by LOGIX Insulated Concrete Forms, Ltd. The label includes the manufacturer’s name, trademark, or other recognized symbol of identification, the product model designation, month and year of manufacture or equivalent, QAI logo with the ‘US’ and “C” identifier, and CAN/ULC S701 Type 2, ASTM C578 Type II, ASTM E84 FSI and SDI Rating, and CAN/ULC S102.2 FSI and SDI Rating. Labels are applied to palletized finished products to ensure visibility on the jobsite.
    • Logix and Element™ ICF complies with specifications for flat-walled ICF in accordance with CAN/ULC S717.1.

      Logix and Element™ ICF complies with specifications for flat-walled insulated concrete forms in accordance with ASTM E2634.

      Logix and Element™ ICF cross ties have a spontaneous ignition temperature ≥ 650oF when evaluated in accordance with ASTM D1929.

      Logix ICF cross ties have a rate of burning of CC2 and Element™ ICF cross ties have a rate of burning of CC1 when evaluated in accordance with ASTM D635.

      Logix and Element™ ICF cross ties have smoke density index < 75 when evaluated in accordance with ASTM D2843.

      Logix ICF has the following allowable fastener load capacities determined in accordance with CAN/ULC S717.1 / ASTM E2634 following ASTM D1761:

      FASTENER

      ALLOWABLE WITHDRAWAL

      ALLOWABLE LATERAL SHEAR

      lbs

      kg

      lbs

      kg

      #6 1-¼ inch Length Coarse Thread Drywall Screw.

      23

      10

      59

      26

      Element™ ICF has the following allowable fastener load capacities determined in accordance with CAN/ULC S717.1 / ASTM E2634 following ASTM D1761:

      FASTENER

      ALLOWABLE WITHDRAWAL

      ALLOWABLE LATERAL SHEAR

      lbs

      kg

      lbs

      kg

      #6 1-5/8inch Length Coarse Thread Drywall Screw.

      37

      16.8

      40

      18.2

      #6 1-5/8inch Length Fine Thread Drywall Screw.

      33.9

      15.4

      21

      9.6

      #8 x 2” Wood Screw

      40

      18.2

      46

      20.8

      #10 x 2” Wood Screw

      42.1

      19.1

      30

      13.5

      #8 x 2” Exterior Deck Screw

      42.3

      19.2

      56

      25.2

      Fasteners are to penetrate through flange of cross-tie at minimum 19 mm (3/4-inch).

      Logix and Element™ ICF Expanded Polystyrene (EPS) Thermal Insulation Type 2 Specifications per CAN/ULC S701.1

      PROPERTY

      LOGIX ICF EPS SPECIFICATIONS

      Thermal Resistance m2*oC/W at 25 mm Thickness

      Minimum 0.70

      Water Vapour Permeance Ng/Pa*s*m2 at 25 mm Thickness

      Maximum 200

      Dimensional Stability % Linear Change

      Maximum 1.5

      Flexural Strength kPa

      Minimum 240

      Water Absorption % Volume

      Maximum 4.0

      Compressive Strength kPa at 10% Deformation

      Minimum 110

      Limiting Oxygen Index %

      Minimum 24

      Logix and Element™ ICF EPS Thermal Insulation Type II Specifications per ASTM C578

      PROPERTY

      LOGIX ICF EPS SPECIFICATIONS

      Compressive Resistance psi at Yield or 10% Deformation

      Minimum 15.0

      Thermal Resistance F*ft2*h/Btu at 1.00 Inch Thickness

      Minimum 4.0

      Flexural Strength psi

      Minimum 35.0

      Water Vapor Permeance Perms at 1.00 Inch Thickness

      Maximum 3.5

      Water Absorption % Volume

      Maximum 3.0

      Dimensional Stability % Change Dimensions

      Maximum 2.0

      Oxygen Index % Volume

      Minimum 24.0

      Density lbs/ft3

      Minimum 1.35

      Logix and Element™ ICF Surface Burning Characteristics per CAN/ULC S102.2

      LOGIX

      COMPONENT

      DENSITY

      MAXIMUM THICKNESS

      FLAME SPREAD INDEX (FSI)

      SMOKE DEVELOPED INDEX (SDI)

      Expanded Polystyrene

      (EPS Panel)

      22 – 29 kg/m3

      100 mm Maximum

      ≤ 250

      ≥ 500

      Logix and Element™ ICF Surface Burning Characteristics per ASTM E841

      LOGIX

      COMPONENT

      DENSITY

      MAXIMUM THICKNESS

      FLAME SPREAD INDEX (FSI)

      SMOKE DEVELOPED INDEX (SDI)

      Expanded Polystyrene

      (EPS Panel)

      1.35 – 1.65 lbs/ft3

      4.0 Inches Maximum

      ≤ 25

      ≤ 450

      1Ceiling Measurement Only. This measurement is conducted through determination of flame spread index and smoke developed index with the removal of any contribution of molten materials ignited on the floor of the tunnel assembly.

      Logix ICF / Element™ ICF UL 1715 Configuration

      Meets requirements with ½ inch thickness gypsum fastened with 2-¼ inch length standard drywall screws at 12 inches on center spacing in the field and around the perimeter. Fasteners must be anchored into Logix and Element™ ICF web ties.

      Logix and Element™ ICF CAN/ULC S101, UL 263, ASTM E119 Fire-Resistance Rated Load-Bearing Wall Assemblies1

      QAI Design #

      Wall Type

      Wall Thickness

      Inches (mm)

      Rating

      B1031-1

      Logix ICF with interior ½-inch (13 mm) gypsum board complying with ASTM C1396.

      4 (102)

      2

      6.25 (159)

      3

      6.252 (159)

      4

      8 (203)

      4

      Element™ ICF with interior 1/2-inch (13 mm) gypsum board complying with ASTM C1396.

      4 (102)

      2

      6 (152)

      3

      8 (203)

      4

      Note 1: The above Logix and Element™ ICF fire-resistance rated wall assemblies allowable load are to be determined by a registered design professional, or authority having jurisdiction in accordance with the applicable codes.
      Note 2: 5/8-inch (16 mm) Type X gypsum board replacing noted ½’’ (13 mm) gypsum is required to meet the 4-hour fire-resistance rating as outlined in QAI design listing B1031-1.

    • Product is marked with labels supplied by LOGIX Insulated Concrete Forms, Ltd. The label includes the manufacturer’s name, trademark, or other recognized symbol of identification, the product model designation, month and year of manufacture or equivalent, QAI logo with the ‘US’ and “C” identifier, and CAN/ULC S701 Type 2, ASTM C578 Type II, ASTM E84 FSI and SDI Rating, and CAN/ULC S102.2 FSI and SDI Rating. Labels are applied to palletized finished products to ensure visibility on the jobsite.
    • Final acceptance of the product in the intended application is to be determined by the authority having jurisdiction.
      Product is to be installed in accordance with the manufacturer’s published installation instructions and the applicable code. Also see QAI CERUS-1005

    • QAI maintains ISO/IEC 17065 accreditations via the International Accreditation Service (IAS) for the United States and Canada. Typically, certifications under this accreditation do not require the Seal of a Professional Engineer in order to be accepted by the authority having jurisdiction. Should a Professional Engineer Seal be needed, please select from the highlighted States / Provinces that are available for this specific manufacturer’s file. If a specific State / Province is not available, you may email info@qai.org to request if a sealed document is available for that jurisdiction.

    The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.

    The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.

    No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.

    Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.

    QAI Logo - Long shape for footer.

    Founded in 1995 by a group of experienced certification and testing experts, QAI is an independent third-party testing, inspection and certification organization which serves the building industry, government and individuals with cost effective solutions through our global, in-house capabilities / services.

    LEARN MORE

    Latest News

    • Join QAI’s Impartiality Committee!

      Be the Voice of Impartiality – Join QAI’s Impartiality Committee!  Are you

      19 December, 2024
    • 2023 Alberta Edition of the National Building Code

      Dear Valued Client, Subject: Announcing the publication of the 2023 Alberta Edition

      5 April, 2024
    • QAI LABORATORIES (QAI) AND ATRONA TEST LABS (ATL) JOIN FORCES TO EXPAND TESTING CAPABILITY

      QAI Laboratories is pleased to announce the acquisition of ATRONA Test Labs,

      18 March, 2024

    Services

    • Service Type
      • Accreditations
      • Product Certification Services
      • Product Testing Services
      • Product Quality Inspection Services
      • Code Approvals
      • QAI Code Evaluation Report Service (CER)

    Industries

    • Building Products Testing and Certification
    • Electrical Safety
    • Plumbing Certification
    • Electromagnetic Compatibility (EMC) Testing & Certification Laboratory
    • Certification of RVs and Park Model Trailers

    Contact

    A tiny US Flag for contact number USA 1(888)540.4024

    A tiny Canada Flag for contact number Canada 1(877)461.8378

    A tiny Europe Flag for contact number Europe info@qai.org

    A tiny China Flag for contact numberChina china-info@qai.org

    A tiny Korea Flag for contact numberS Korea asia-info@qai.org
    Copyright © 2023 QAI Laboratories. All rights reserved.
    • Contact
    • SERVICES
      • Core Services
        • Product Certification Services
        • Product Testing Services
        • Product Quality Inspection Services
        • Accreditations
        • QAI Code Evaluation Report Service (CER)
      • Industry Focus
        • Electrical Safety
        • EMC EMI
        • Building Products Testing and Certification
        • Fenestration Testing and Certification
        • Plumbing Certification
          • EPA WaterSense® Product Certification
        • Testing and certification of Gas Products
        • Certification of RVs and Park Model Trailers
        • Transport Canada
      • Solutions
        • Green Product Certification Services
        • Solar and Photovoltaic Panel Fire Resistance Testing and Racking System Certification
        • Fire and Flammability Testing for Materials
        • Hazardous Location (HazLoc) Explosion Proof Testing and Certification
        • China Wireless SRRC Certification
        • China Compulsory Certification (CCC)
        • Special Inspections on Electrical Devices
        • Electrical Safety Test Medical Equipment_old (replaced on Nov 18 2024)
        • Semiconductor Safety Services
      • Listing Directory
        • Building Products – Directory
        • Electrical Products – Directory
        • ICC-ES Report Holders – Directory
        • Plumbing Products – Directory
        • Windows & Doors – Directory
    • Company
    QAI
    DG_test-Get a Quote(Title)

    This is the content

    Please use the form below to get in touch.

    • This field is for validation purposes and should be left unchanged.