Logix Brands, Ltd.
Building Products Listing Program
- Logix Brands, Ltd.
- Insulated Concrete Forms (ICF)
- Whistler, BC Canada
- B1031-1
- B1031-1 ED. 3
- September 27, 2010
- January 25, 2022
- N/A
-
CAN/ULC S717.1 Standard for Flat Wall Insulating Concrete Form (ICF) Systems. ASTM E2634 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems. ASTM D1761 Standard Test Methods for Mechanical Fasteners in Wood and Wood-Based Materials. CAN/ULC S701.1 Thermal Insulation, Polystyrene, Boards and Pipe Covering. ASTM C578 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation. CAN/ULC S102.2 Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials. UBC 26-3 Room Fire Test Standard for Interior of Foam Plastic Systems. ASTM D635 Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position. ASTM D1929 Standard Test Method for Determining Ignition Temperature of Plastics. ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials. CAN/ULC S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials. UL 263 Standard for Fire Tests of Building Construction and Materials. -
LOGIX Insulated Concrete Forms (ICF)
-
Product is marked with labels supplied by Logix Brands Ltd. Products are marked in a permanent manner where it is readily visible after installation with the following:
a) Manufacturer’s name or trademark
b) Product model designation
c) Month and year of manufacture
d) QAI file Number: B1031-1
e) CAN/ULC S701.1 Type 2, ASTM C578 Type II, ASTM E84 FSI and SDI Rating (FSI ≤ 25 / SDI ≤ 450) and CAN/ULC S102.2 FSI and SDI ratings (FSI ≤ 230 / SDI ≥ 500).
f) QAI logo shown here: - Product is marked with labels supplied by LOGIX Insulated Concrete Forms, Ltd. The label includes the manufacturer’s name, trademark, or other recognized symbol of identification, the product model designation, month and year of manufacture or equivalent, QAI logo with the ‘US’ and “C” identifier, and CAN/ULC S701 Type 2, ASTM C578 Type II, ASTM E84 FSI and SDI Rating, and CAN/ULC S102.2 FSI and SDI Rating. Labels are applied to palletized finished products to ensure visibility on the jobsite.
-
Logix ICF complies with specifications for flat-walled ICF in accordance with CAN/ULC S717.1.
Logix ICF complies with specifications for flat-walled insulated concrete forms in accordance with ASTM E2634.
Logix ICF cross ties have a spontaneous ignition temperature ≥ 650oF when evaluated in accordance with ASTM D1929.
Logix ICF cross ties have a rate of burning of CC2 when evaluated in accordance with ASTM D635.
Logix ICF has the following allowable fastener load capacities determined in accordance with CAN/ULC S717.1 / ASTM E2634 following ASTM D1761:
FASTENER ALLOWABLE WITHDRAWAL ALLOWABLE LATERAL SHEAR lbs kg lbs kg #6 1-¼ inch Length Coarse Thread Drywall Screw. 23 10 59 26 Fasteners are to penetrate through flange of cross-tie.
Logix ICF Expanded Polystyrene (EPS) Thermal Insulation Type 2 Specifications per CAN/ULC S701.1
PROPERTY LOGIX ICF EPS SPECIFICATIONS Thermal Resistance
m2*oC/W at 25 mm ThicknessMinimum 0.70 Water Vapour Permeance
Ng/Pa*s*m2 at 25 mm ThicknessMaximum 200 Dimensional Stability
% Linear ChangeMaximum 1.5 Flexural Strength
kPaMinimum 240 Water Absorption
% VolumeMaximum 4.0 Compressive Strength
kPa at 10% DeformationMinimum 110 Limiting Oxygen Index
%Minimum 24 Logix ICF EPS Thermal Insulation Type II Specifications per ASTM C578
PROPERTY LOGIX ICF EPS SPECIFICATIONS Compressive Resistance
psi at Yield or 10% DeformationMinimum 15.0 Thermal Resistance
F*ft2*h/Btu at 1.00 Inch ThicknessMinimum 4.0 Flexural Strength
psiMinimum 35.0 Water Vapor Permeance
Perms at 1.00 Inch ThicknessMaximum 3.5 Water Absorption
% VolumeMaximum 3.0 Dimensional Stability
% Change DimensionsMaximum 2.0 Oxygen Index
% VolumeMinimum 24.0 Density
lbs/ft3Minimum 1.35 Logix ICF Surface Burning Characteristics per CAN/ULC S102.2
LOGIX
COMPONENTDENSITY MAXIMUM THICKNESS FLAME SPREAD INDEX (FSI) SMOKE DEVELOPED INDEX (SDI) Expanded Polystyrene
(EPS Panel)22 – 29 kg/m3 100 mm Maximum ≤ 250 ≥ 500 Logix ICF Surface Burning Characteristics per ASTM E841
LOGIX
COMPONENTDENSITY MAXIMUM THICKNESS FLAME SPREAD INDEX (FSI) SMOKE DEVELOPED INDEX (SDI) Expanded Polystyrene
(EPS Panel)1.35 – 1.65 lbs/ft3 4.0 Inches Maximum ≤ 25 ≤ 450 1Ceiling Measurement Only. This measurement is conducted through determination of flame spread index and smoke developed index with the removal of any contribution of molten materials ignited on the floor of the tunnel assembly.
Logix ICF UBC 26-3 Configuration
Meets requirements with ½ inch thickness gypsum fastened with 2-¼ inch length standard drywall screws at 12 inches on center spacing in the field and around the perimeter. Fasteners must be anchored into Logix ICF web ties.
Logix ICF CAN/ULC S101, UL 263, ASTM E119 Fire-Resistance Rated Load-Bearing Wall Assemblies
QAI DESIGN # Wall Type Wall Thickness Inches (mm) Rating B1031-1 Logix ICF with interior 1/2’’ (13 mm) gypsum board complying with ASTM C1396. 4 (102) 2 6.25 3 6.251 4 8 4 Note 1: 5/8’’ (16 mm) Type X gypsum board replacing noted ½’’ (13 mm) gypsum is required to meet the 4-hour fire-resistance rating as outlined in QAI design listing B1031-1.
The above Logix ICF fire-resistance rated wall assemblies allowable load are to be determined by a registered design professional, or authority having jurisdiction in accordance with the applicable codes.
Notes:
Final acceptance of the product in the intended application is to be determined by the authority having jurisdiction.
Product is to be installed in accordance with the manufacturer’s published installation instructions by qualified installing personnel. Also see QAI CERus-1005
- Product is marked with labels supplied by LOGIX Insulated Concrete Forms, Ltd. The label includes the manufacturer’s name, trademark, or other recognized symbol of identification, the product model designation, month and year of manufacture or equivalent, QAI logo with the ‘US’ and “C” identifier, and CAN/ULC S701 Type 2, ASTM C578 Type II, ASTM E84 FSI and SDI Rating, and CAN/ULC S102.2 FSI and SDI Rating. Labels are applied to palletized finished products to ensure visibility on the jobsite.
-
QAI maintains ISO/IEC 17065 accreditations via the International Accreditation Service (IAS) for the United States and Canada. Typically, certifications under this accreditation do not require the Seal of a Professional Engineer in order to be accepted by the authority having jurisdiction. Should a Professional Engineer Seal be needed, please select from the highlighted States / Provinces that are available for this specific manufacturer’s file. If a specific State / Province is not available, you may email info@qai.org to request if a sealed document is available for that jurisdiction.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI. No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing. Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.