VAGA Refrigeration, Inc.
Building Products Listing Program
- VAGA Refrigeration, Inc.
- Insulated Metal Panels
- Trenton, Ontario Canada
- B1154
- B1154-1 Edition 1
- July 17, 2024
- July 17, 2024
- N/A
-
CAN/ULC-S102-18
“Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.”CAN/ULC-S127-14
“Standard Corner Wall Method of Test for Flammability Characteristics of Non-Metling Foam PlasticBuilding Materials”.
CAN/ULC-S138-06
“Standard Method of Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration”ASTM C518-17
“Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus”. -
VAGA Insulated Metal Panels (IMP) for walk-in coolers and freezers of the following types:
•V-TAG (Tongue and Groove) Panels
•V-CAM (Camlock) Panels -
Each panel is marked with a permanent label containing the following information:
a)Manufacturers name or recognized trademark
b)Product name
c)Traceability code.
d)QAI file number: B1154
e)CAN/ULC-S102 Flame Spread Index and Smoke Developed Index
f)CAN/ULC-S138 compliant.
g)Panel thickness requirements.
h)QAI logo shown here: -
VAGA V-TAG and V-CAM IMP have the following performance properties when evaluated per CAN/ULC S102:
Model(s)
Flame Spread Index
Smoke Developed Index
Thickness Max. (mm)
Density Max. (kg/m3)
V-TAG and V-CAM foam core
(w/o Steel Skin)
≤ 5001
> 500
152
40
V-TAG and V-CAM Panels
(with Steel Skin including panel joint gasketing2)
≤ 25
≤ 500
152
40
1: Flame spread determined in accordance with CAN/ULC-S127 as required by CAN/ULC-S102 for thermosetting charring foam.
2: Joint treatment can include gasketing or butyl sealant. Finished panel joint requires Nuco Self-Seal Non-Sag GG-200 sealant continuous applied to seal over joint and underlying gaskets and sealant and shall include panel fastening with screws at top and bottom of joint.
VAGA V-Tag and Camlock IMP have the following ratings determined in accordance with CAN/ULC-S138:
Design Listing:
Model(s)
CAN/ULC-S1381
V-TAG and V-CAM IMP
Sprinklered Room Compliant when equipped with standard response 68oC (155oF) activation temperature, pendant style listed sprinklers. Joints can include optional gasketing or butyl sealant. After installation, joint is to be sealed with Nuco Self-Seal Non-Sag GG-200 silicone sealant applied to continuously cover joint, and panels are fastened at joint top and bottom. Installation requires 51 mm x 51 mm (2-inch x 2-inch) steel angle trim at wall to ceiling, wall to floor, and wall corner intersections.
Note 1: VAGA IMP found to comply with 2020 National Building Code of Canada, Section 3.1.5.7 Factory-Assembled Panels for use as walk-in cooler or freezer panels in sprinklered buildings, based on compliance with CAN/ULC-S138 where the interior finish rating meets flame spread ratings noted in CAN/ULC S102 above for V-Tag Panels where joints are treated as noted.
VAGA V-TAG and V-CAM IMP have the following thermal resistivity and minimum thickness required for compliance with National Resources Canada (NRCan) Energy Efficiency Regulation requirements when evaluated per ASTM C518 for applications noted1:
APPLICATION
THERMAL RESISTIVITY m*K/W (hr*ft2*oF / Btu*in)
REQUIRED MINIMUM THICKNESS, mm (inches)
Walk-In Cooler Mean 12.8oC (55oF)
Structural (Wall)
49.0 (7.1)
89 (3.5) @ RSI 4.40 m2*K/W
Floor
101 (4) @ RSI 4.93 m2*K/W
Walk-In Freezer Mean -6.7oC (20oF)
Structural (Wall)
55.5 (8.0)
102 (4) @ RSI 5.64 m2*K/W
Floor
89 (3.5) @ RSI 4.93 m2*K/W
Note 1: Evaluation was conducted in accordance with 10 CFR-2017, Part 431, Subpart R, Appendix B.
Notes:
Products must be installed with the manufacturer’s published installation instructions and in accordance with the building codes recognized by the authority having jurisdiction.Listed manufacturers are subject to on-going inspections by QAI to ensure that the products outlined above remains as it is listed.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.