Ecospan Profiles Inc.
Building Products Listing Program
- Ecospan Profiles Inc.
- Insulated Metal Panels
- High Bluff, Manitoba Canada
- B1113
- B1113-1
- January 31, 2019
- November 2, 2023
- N/A
-
CAN/ULC S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies
CAN/ULC S127 Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials.
CAN/ULC S126 Standard Method of Test for Fire Spread Under Roof-Deck Assemblies
CAN/ULC S138 Standard Method of Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration
CAN/ULC S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials
ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials
NFPA 286 Standard Methods of Fire Tests for Evaluating Contribution for Wall and Ceiling Interior Finish to Room Fire Growth. -
Edge Wall Panels
Skyline Wall Panels
Skyline Roof Panels -
Ecospan Profiles Inc. panels surface burning characteristics determined in accordance with CAN/ULC-S102:
Model(s) Flame Spread Index Smoke Developed Index Thickness Max. (mm) Density Max. kg/m3) Edge Wall
Skyline Wall
Skyline Roof
(w/o Steel Skin)≤ 3501 ≤ 250 51 – 152 40 Edge Wall
Skyline Wall
Skyline Roof
(with Steel Skin Including Joint)≤ 25 ≤ 200 51 – 152 40 Note 1: Flame spread index determined in accordance with CAN/ULC S127.
Ecospan Profiles Inc. panels surface burning characteristics complying with CAN/ULC S126:
Model(s) Results Thickness Max. (mm) Density Max. (kg/m3) Skyline Roof
(with Steel Skin)Complies 51 – 152 40 Ecospan Profiles Inc. panels surface burning characteristics determined in accordance with ASTM E84:
Model(s) Flame Spread Index Smoke Developed Index Thickness Max. (inches) Density Max. lbs/ft3) Edge Wall
Skyline Wall
Skyline Roof
(w/o Steel Skin)≤ 25 ≤ 450 2 – 6 2.5 Edge Wall
Skyline Wall
Skyline Roof
(with Steel Skin)≤ 25 ≤ 450 2 – 6 2.5 Ecospan Profiles Inc. panels products ratings determined in accordance with CAN/ULC-S138:
QAI Design# Model(s) CAN/ULC-S138 B1113-1a2 Edge Wall
Skyline Wall
Skyline RoofSprinklered Room Compliant when equipped with 68oC (155oF) activation temperature, pendant style listed sprinklers.
Fastener at top and bottom panels for panel connection are required. Corners treated with flashing, mechanically secured.
Optional, butyl caulking can be applied at joints.Note 2: The above assembly has been evaluated and found compliant for Protection of Foam Plastic in Combustible Construction as outlined in Section 3.1.4.2 of the 2020 National Building Code of Canada (NBC).
The above assembly has been evaluated and found compliant for Factory Assembled Panels for use in Non-Combustible Construction for buildings that are sprinklered, < 18 meters high, have no Group A Group B or Group C major occupancies, with the panel having no air spaces, as outlined in Section 3.1.5.7 of the 2020 NBC and where panels are used in application where flame spread ratings required are ≤ 25.
Ecospan Profiles Inc. panels products evaluated to NFPA 286:
QAI Design# Model(s) NFPA 286 Details B1113-1b3 Edge Wall
Skyline Wall
Skyline RoofFastener at top and bottom panels for panel connection are required. Corners treated with flashing, mechanically secured.
Optional, butyl caulking can be applied at joints.Note 3: The above assembly has been evaluated and found compliant for installation and use without a code prescribed thermal barrier, based on Section 2603.9 Special Approval of International Building Code 2021/2018/2015.
Ecospan Profiles Inc. products complying with CAN/ULC-S101 15-minute stay in place when used as wall panels:
QAI Design # Model(s) Fire Endurance Openings Edge
Skyline Wall15 Minutes No Openings Developed.
The materials, products or systems listed in this directory have been qualified to bear the QAI Listing Mark under the conditions stated with each Listing. Only those products bearing the QAI Listing Mark are considered to be listed by QAI.
The standard herein listed is the currently accepted version within the relevant certification scheme, code or other requirements unless otherwise noted. Transition periods may apply. Upon request, QAI will provide information about the validity of any of its certifications.
No warrantee is expressed or implied, and no guarantee is provided that any jurisdictional authority will accept the Listing found herein. The appropriate authorities should be contacted regarding the acceptability of any given Listing.
Visit the QAI Online Listing Directory located at www.qai.org for the most up to date version of this Listing and to validate that this QAI Listing is active. Questions regarding this listing may be directed to info@qai.org. Please include the listing number in the request.